Comparison of efficiency and safety between dual-clip and rubber band-assisted ESD and conventional ESD for colonic lateral spreading tumors (LSTs) with different levels of technical difficulty: a retrospective case–control study

Author:

Ma Xingbin,Ma Huaiyuan,Gao Tao,Cao Jingrun,Liu Chengxia,Niu Qiong

Abstract

Abstract Background Dual-clip and rubber band-assisted endoscopic submucosal dissection (DCRB-ESD) is a useful technique in the management of lateral spreading tumors (LSTs) of the colon and is suggested by researchers compared with conventional ESD (C-ESD). The aim of this retrospective study is to further analyze the efficiency and safety of DCRB-ESD in a setting with varying technical difficulties. Methods Patients who underwent endoscopic treatment (DCRB-ESD or C-ESD) due to LSTs between Jan 1st, 2019 and Jan 1st, 2022, were retrospectively collected. Patients were classified into the following two groups: the DCRB-ESD group (n = 46) and the C-ESD group (n = 81). Baselines were compared and propensity score matching (PSM) was employed to manage the heterogeneity. The technical difficulty and outcomes of the two groups were evaluated based on a semiquantitative model (CS-CRESD) previously described. Results The baseline characteristics of the two groups were balanced except sex and LST classification before PSM and were corrected after PSM. The median ESD operation time of DCRB-ESD was shorter than that of C-ESD (32 vs 41 and 30 vs 44 before and after PSM respectively, P < 0.05). The operation durations of cases with different CS-CRESD scores were different (P < 0.05). In the subgroup with a score of 0, DCRB-ESD showed no advantage than C-ESD in terms of operation duration before and after PSM. In subgroups with a score of 1–3, DCRB-ESD was faster than C-ESD. In subgroups with a score of 4–5, the between-group operation duration was not significantly different due to the limited number of cases, although the median time of DCRB-ESD was shorter. The R0 resection rates, curative resection, complications, and additional surgery in both groups were not significantly different. No adverse events, such as a clip falling off or rubber band rupturing occurred during this study. Conclusion DCRB-ESD was an efficient and safe procedure in the management of colonic LSTs. With DCRB-ESD, the operation duration of difficult cases can be shortened without sacrificing complication risk. However, not all cases would benefit from DCRB-ESD. For easy cases (CS-CRESD score = 0), DCRB-ESD may not be prior to C-ESD by experienced endoscopists. A pre-ESD technical difficulty evaluation was recommended to decide whether to perform DCRB-ESD or not.

Publisher

Springer Science and Business Media LLC

Subject

Gastroenterology,General Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3