Abstract
Abstract
Background
It is unclear if the 99mTc-sodium phytate (99mTc-SP) is as reliable as the gold-standard 99mTc-sulfur colloid (99mTc-SC) for gastric emptying scintigraphy (GES). This study is aimed to compare the emptying rates of both radiotracers in a prospective, randomized cross-over trial and to determine the normative data of a healthy multi-ethnic Asian population.
Methods
Out of the 44 healthy individuals screened, 31 (14 females; mean age: 28.4 ± 7.0 years) were enrolled and underwent GES using the standardized egg-white meal. All participants were randomly assigned to either 99mTc-SP or 99mTc-SC on the first GES session before crossed over to the other formulation after 2 weeks.
Results
Both kits achieved the radiochemical purities of > 95%. The median rate (95th upper normative limit) of gastric emptying, reported as total gastric meal retention between 99mTc-SP and 99mTc-SC, was found to be comparable at all measured time points: 0.5 h [85.0% (96.6%) vs. 82.0% (94.0%)], 1 h [70.0% (86.4%) vs. 65.0% (86.6%)], 2 h [31.0% (55.8%) vs. 25.0% (64.4%)], 3 h [7.0% (26.3%) vs. 5.0% (29.9%)], and 4 h [3.0% (10.3%) vs. 2.0% (9.9%)]; P > 0.05. In addition, both radiotracers correlated well (Kendall’s Tau (τ) coefficient = 0.498, P < 0.001) and presented with a good agreement at the 4th-hour time frame based on the Bland-Altman plot analysis.
Conclusions
99mTc-SP is a valid radiotracer alternative to 99mTc-SC for routine GES examination. The normative values for both radiotracers have also been determined for the healthy multi-ethnic Asian population.
Trial registration
This trial was registered retrospectively in the Thai Clinical Trials Registry on May 23rd, 2020 (Identifier: TCTR20200526004; http://www.clinicaltrials.in.th/index.php?tp=regtrials&menu=trialsearch&smenu=fulltext&task=search&task2=view1&id=6296).
Funder
Universiti Sains Malaysia
Publisher
Springer Science and Business Media LLC
Subject
Gastroenterology,General Medicine
Reference26 articles.
1. Maurer AH, Abell T, Bennett P, Diaz JR, Harris LA, Hasler W, et al. Appropriate use criteria for gastrointestinal transit scintigraphy. J Nucl Med. 2020;61(3):11N–7N.
2. Goyal RK, Guo Y, Mashimo H. Advances in the physiology of gastric emptying. Neurogastroenterol Motil. 2019;31(4):e13546.
3. Parkman HP. Assessment of gastric emptying and small-bowel motility: scintigraphy, breath tests, manometry, and SmartPill. Gastrointest Endosc Clin N Am. 2009;19(1):49–55.
4. Szarka LA, Camilleri M. Methods for measurement of gastric motility. Am J Physiol-Gastrointest Liver Physiol. 2009;296(3):G461–75.
5. Abell TL, Camilleri M, Donohoe K, Hasler WL, Lin HC, Maurer AH, et al. Consensus recommendations for gastric emptying scintigraphy: a joint report of the American Neurogastroenterology and motility society and the Society of Nuclear Medicine. J Nucl Med Technol. 2008;36(1):44–54.
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献