Optimization of impedance-measured reflux events in GORD utilizing acid exposure time

Author:

Horton Anthony J.,Clayton Steven B.ORCID

Abstract

Abstract Background Combining impedance with pH monitoring improves the detection and characterization of gastro-oesophageal reflux (GOR), yet the two modalities frequently differ in GOR quantification. Ambulatory 24-h pH-impedance monitoring often reveals more significant oesophageal acid exposure than impedance-measured reflux activity in patients with symptomatic gastro-oesophageal reflux disease (GORD). The purpose of this study is to elucidate the discrepancies between these modalities by assessing the predictive accuracy of impedance compared to acid exposure standards. Methods A single-institution, retrospective review of sequential 24-h pH-impedance results of 72 patients with symptomatic GOR off anti-secretory therapy was conducted. Reflux events measured by impedance were stratified by patient position and compared to oesophageal acid exposure time (AET). Oesophageal AET limits for GORD detection were utilized as gold standards to generate serial receiver operator characteristics (ROC) curves to assess the sensitivity and specificity of current impedance GORD detection limits and identify optimized impedance standards based on area under the curve (AUC) analysis. Results Mean total AET time was 10.5% (± 9.9%), and 63.8% of patients had elevated AET. By impedance, median GOR frequency was 43 (IQR 21–68), and 22.2% exceeded conventional GOR frequency limits of normal. ROC curve analysis revealed the current impedance standard of > 73 GOR events has a sensitivity of 32.6% and specificity of 96.5% (AUC 0.74) for GORD detection. By AUC analysis, an impedance threshold of > 41 GOR events is optimal for GORD detection (sensitivity 69.6%, specificity 80.7%, AUC 0.83). Conclusion Conventional impedance standards for abnormal GOR frequency are weakly sensitive for the detection of GORD, providing a possible explanation to discrepancies in AET and impedance interpretation. Lowering impedance-measured GOR frequency limits to > 41 optimizes sensitivity and specificity while increasing congruence between pH and impedance metrics.

Publisher

Springer Science and Business Media LLC

Subject

Gastroenterology,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3