Measuring distance from the incisors to the esophageal cancer by FDG PET/CT: endoscopy as the reference

Author:

Hsu Szu-Wei,Chang Jeffrey S.,Chang Wei-Lun,Lin Forn-Chia,Chiu Nan-Tsing

Abstract

Abstract Background Using endoscopy as the reference, this study evaluated the accuracy of 18F-fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT) in measuring distance from the incisors to the PET detectable esophageal cancer. If there is high concordance between endoscopic and PET measurements, our results may provide a basis to use FDG PET/CT in cooperation with endoscopic measurement to localize those PET/CT and CT undetectable esophageal tumors for radiotherapy planning. Materials Esophageal cancer patients with pretreatment endoscopy and FDG PET/CT detectable esophageal tumors were recruited retrospectively. The distances from the incisors to the proximal esophageal tumor margins were determined by endoscopy and by the sagittal images of FDG PET/CT. The endoscopic measurement was used as the comparative reference. A nuclear medicine doctor and a radiation oncologist each performed the FDG PET/CT measurement twice for every patient. We analyzed the differences in these measurements, and assessed agreement and reproducibility of the results by the intraclass correlation coefficient (ICC). Results Thirty-four patients, with 35 esophageal tumors, were included. By endoscopy and FDG PET/CT, the mean distances from the incisors to the proximal esophageal tumor margin were 27.3 ± 6.4 cm (range 17.1–40.0 cm) and 26.8 ± 6.3 cm (range 15.7–41.3 cm), respectively. The mean absolute differences between the endoscopic and four FDG PET/CT measurements ranged from 1.129 to 1.289 cm (SD: 0.98–1.19). The measurement agreement between FDG PET/CT and endoscopy by ICC was between 0.962 and 0.971. The intra- and interobserver reproducibilities of the two readers were excellent (intraobserver ICC: 0.985, 0.996; interobserver ICC: 0.976–0.984). Conclusions FDG PET/CT was in high agreement with endoscopy in measuring the distance from the incisors to the proximal esophageal tumor margin. For FDG PET/CT and CT undetectable esophageal cancer, incorporation of the endoscopic measurement with PET/CT might be a way for making radiotherapy plan.

Funder

National Cheng Kung University Hospital

Publisher

Springer Science and Business Media LLC

Subject

Gastroenterology,General Medicine

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3