Author:
Jin Seung Oh,Kim Jae Gon,Lee Soo Yeol,Kwon Oh-Kyong
Abstract
Abstract
Background
In sparse-view CT imaging, strong streak artifacts may appear around bony structures and they often compromise the image readability. Compressed sensing (CS) or total variation (TV) minimization-based image reconstruction method has reduced the streak artifacts to a great extent, but, sparse-view CT imaging still suffers from residual streak artifacts. We introduce a new bone-induced streak artifact reduction method in the CS-based image reconstruction.
Methods
We firstly identify the high-intensity bony regions from the image reconstructed by the filtered backprojection (FBP) method, and we calculate the sinogram stemming from the bony regions only. Then, we subtract the calculated sinogram, which stands for the bony regions, from the measured sinogram before performing the CS-based image reconstruction. The image reconstructed from the subtracted sinogram will stand for the soft tissues with little streak artifacts on it. To restore the original image intensity in the bony regions, we add the bony region image, which has been identified from the FBP image, to the soft tissue image to form a combined image. Then, we perform the CS-based image reconstruction again on the measured sinogram using the combined image as the initial condition of the iteration. For experimental validation of the proposed method, we take images of a contrast phantom and a rat using a micro-CT and we evaluate the reconstructed images based on two figures of merit, relative mean square error and total variation caused by the streak artifacts.
Results
The images reconstructed by the proposed method have been found to have smaller streak artifacts than the ones reconstructed by the original CS-based method when visually inspected. The quantitative image evaluation studies have also shown that the proposed method outperforms the conventional CS-based method.
Conclusions
The proposed method can effectively suppress streak artifacts stemming from bony structures in sparse-view CT imaging.
Publisher
Springer Science and Business Media LLC
Subject
Radiology Nuclear Medicine and imaging,Biomedical Engineering,General Medicine,Biomaterials,Radiological and Ultrasound Technology
Reference30 articles.
1. Bian JG, Siewerdsen JH, Han XA, Sidky EY, Prince JL, Pelizzari CA, Pan XC: Evaluation of sparse-view reconstruction from flat-panel-detector cone-beam CT. Phys Med Biol 2010, 55: 6575–6599. 10.1088/0031-9155/55/22/001
2. Ritschl L, Bergner F, Fleischmann C, Kachelriess M: Improved total variation-based CT image reconstruction applied to clinical data. Phys Med Biol 2011, 56: 1545–1561. 10.1088/0031-9155/56/6/003
3. Li XL, Luo SQ, Talbert AJ, Eisner RL, DiBianca FA: A compressed sensing-based iterative algorithm for CT reconstruction and its possible application to phase contrast imaging. Biomed Eng Online 2011., 10:
4. Brooks RA, Glover G, Talbert AJ, Eisner RL, DiBianca FA: Aliasing: a source of streaks in computed tomograms. J Comput Assist Tomo 1979, 3: 511–518. 10.1097/00004728-197908000-00014
5. Crawford CR, Kak AC: Aliasing artifacts in computerized tomography. Appl Optics 1979, 18: 3704–3711. 10.1364/AO.18.003704
Cited by
17 articles.
订阅此论文施引文献