Abstract
Background
The electroencephalography (EEG) signals are known to involve the firings of neurons in the brain. The P300 wave is a high potential caused by an event-related stimulus. The detection of P300s included in the measured EEG signals is widely investigated. The difficulties in detecting them are that they are mixed with other signals generated over a large brain area and their amplitudes are very small due to the distance and resistivity differences in their transmittance.
Methods
A novel real-time feature extraction method for detecting P300 waves by combining an adaptive nonlinear principal component analysis (ANPCA) and a multilayer neural network is proposed. The measured EEG signals are first filtered using a sixth-order band-pass filter with cut-off frequencies of 1 Hz and 12 Hz. The proposed ANPCA scheme consists of four steps: pre-separation, whitening, separation, and estimation. In the experiment, four different inter-stimulus intervals (ISIs) are utilized: 325 ms, 350 ms, 375 ms, and 400 ms.
Results
The developed multi-stage principal component analysis method applied at the pre-separation step has reduced the external noises and artifacts significantly. The introduced adaptive law in the whitening step has made the subsequent algorithm in the separation step to converge fast. The separation performance index has varied from -20 dB to -33 dB due to randomness of source signals. The robustness of the ANPCA against background noises has been evaluated by comparing the separation performance indices of the ANPCA with four algorithms (NPCA, NSS-JD, JADE, and SOBI), in which the ANPCA algorithm demonstrated the shortest iteration time with performance index about 0.03. Upon this, it is asserted that the ANPCA algorithm successfully separates mixed source signals.
Conclusions
The independent components produced from the observed data using the proposed method illustrated that the extracted signals were clearly the P300 components elicited by task-related stimuli. The experiment using 350 ms ISI showed the best performance. Since the proposed method does not use down-sampling and averaging, it can be used as a viable tool for real-time clinical applications.
Publisher
Springer Science and Business Media LLC
Subject
Radiology Nuclear Medicine and imaging,Biomedical Engineering,General Medicine,Biomaterials,Radiological and Ultrasound Technology
Reference47 articles.
1. Berger H: Uber das elektroenkephalogram des menschen. Archiv fur Psychiatrie und Nervenkrankheiten 1929, 87: 527–570. 10.1007/BF01797193
2. Niedermeyer E, da Silva FL: Electroencephalography: Basic principles, clinical applications, and related fields. 5th edition. Lippincot Williams & Wilkins; 2004.
3. Wang JT, Young GB, Connolly JF: Prognostic value of evoked responses and eventrelated brain potentials in coma. Can J Neurol Sci 2004, 31: 438–450.
4. Rousseff RT, Tzvetanov P, Atanassova PA, Volkov I, Hristova I: Correlation between cognitive P300 changes and the grade of closed head injury. Electromyogr Clin Neurophysiol 2006, 46: 275–282.
5. Pritchett S, Zilberg E, Xu ZM, Myles P, Brown I, Burton D: Peak and averaged bicoherence for different EEG patterns during general anaesthesia. Biomedical Engineering Online 2010, 9: 76. 10.1186/1475-925X-9-76
Cited by
57 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献