Dosimetric effects of supine immobilization devices on the skin in intensity-modulated radiation therapy for breast cancer: a retrospective study

Author:

Lv Ran,Yang Guangyi,Huang Yongzhi,Wang YanhongORCID

Abstract

Abstract Background The dose perturbation effect of immobilization devices is often overlooked in intensity-modulated radiation therapy (IMRT) for breast cancer (BC). This retrospective study assessed the dosimetric effects of supine immobilization devices on the skin using a commercial treatment planning system. Methods Forty women with BC were divided into four groups according to the type of primary surgery: groups A and B included patients with left and right BC, respectively, who received 50 Gy radiotherapy in 25 fractions after radical mastectomy, while groups C and D included patients with left and right BC, respectively, who received breast-conservation surgery (BCS) and 40.05 Gy in 15 fractions as well as a tumor bed simultaneous integrated boost to 45 Gy. A 0.2-cm thick skin contour and two sets of body contours were outlined for each patient. Dose calculations were conducted for the two sets of contours using the same plan. The dose differences were assessed by comparing the dose-volume histogram parameter results and by plan subtraction. Results The supine immobilization devices for BC resulted in significantly increased skin doses, which may ultimately lead to skin toxicity. The mean dose increased by approximately 0.5 and 0.45 Gy in groups A and B after radical mastectomy and by 2.7 and 3.25 Gy in groups C and D after BCS; in groups A–D, the percentages of total normal skin volume receiving equal to or greater than 5 Gy (V5) increased by 0.54, 1.15, 2.67, and 1.94%, respectively, while the V10 increased by 1.27, 1.83, 1.36, and 2.88%; the V20 by 0.85, 1.87, 2.76, and 4.86%; the V30 by 1.3, 1.24, 10.58, and 11.91%; and the V40 by 1.29, 0.65, 10, and 10.51%. The dose encompassing the planning target volume and other organs at risk, showed little distinction between IMRT plans without and with consideration of immobilization devices. Conclusions The supine immobilization devices significantly increased the dose to the skin, especially for patients with BCS. Thus, immobilization devices should be included in the external contour to account for dose attenuation and skin dose increment. Trial registration This study does not report on interventions in human health care.

Funder

Science and Technology Planning Project of Quanzhou Science and Technology Bureau

Fujian Provincial Health and Family planning Commission Research Talent training project

Publisher

Springer Science and Business Media LLC

Subject

Cancer Research,Genetics,Oncology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3