Author:
Zhao Guang Sheng,Liu Song,Yang Liang,Li Chuang,Wang Ruo Yu,Zhou Jun,Zhang Yue Wei
Abstract
Abstract
Background
To observe the medium- and long-term clinical efficacy and safety of radioactive 125I seed implantation for refractory malignant tumours based on CT-guided 3D template-assisted technique.
Methods
Twenty-five patients with refractory malignant tumours who underwent radioactive 125I seed implantation based on CT-guided 3D template-assisted technique were selected. The post-operative adverse reactions were recorded. The number of puncture needles and particles used in the operation, dosimetric parameters, post-operative physical strength scores, and tumour response were statistically analysed. The overall survival time and survival rate were calculated, and the effect and prognosis were assessed.
Results
125I seed implantation was successful in all patients without serious complications. The average number of implanted puncture needles was 17 (19.12 ± 13.00), and the median number of particles was 52 (55.12 ± 32.97). D90 in the post-operative clinical target volume (CTV) (93.24 ± 15.70 Gy) was slightly lower than that in the pre-operative CTV (93.92 ± 17.60 Gy; P > 0.05). The D90 in the post-operative planning target volume (PTV) (142.16 ± 22.25 Gy) was lower than the pre-operative PTV (145.32 ± 23.48 Gy; P > 0.05). The tumour responses at 6 months post-operatively: complete remission (CR), 20% (5/25); partial remission (PR), 48% (12/25); stable disease (SD), 24% (6/25); progressive disease (PD), 8% (2/25); CR + PR, 68% (17/25); and local control rate, 92% (23/25). The 6-, 12-, and 24-month survival rates were 100, 88, and 52%, respectively. The post-operative physical strength score (Karnofsky performance score, KPS) exhibited a gradual trend towards recovery, which rose to the highest value 12 months after implantation and then decreased slightly, but the average score was still > 90 points. There was one intra-operative pneumothorax, and two patients with superficial malignant tumours developed skin ulcerations. Multivariate analysis of prognosis showed that tumour sites and types were independent risk factors affecting survival. The number of needles and particles and template types were not the factors.
Conclusions
3D template combined with CT-guided radioactive 125I seed implantation can improve the rational distribution of radiation dose in the tumour target area because accurate radioactive 125I particle implantation was achieved. This technique has fewer complications and can further extend the overall survival and improve the quality of life.
Trial registration
Registration number: ChiCTR2000034566 2020/7/10 0:00:00
Retrospectively registered.
Publisher
Springer Science and Business Media LLC
Subject
Cancer Research,Genetics,Oncology
Cited by
17 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献