Abstract
Abstract
Background
When the resected specimen is sent for intraoperative margin assessment, all margins are grossly checked, and selected margins undergo a frozen section (FS) examination. Therefore, there is a possibility of sampling error. This study evaluated the effectiveness of using toluidine blue (TB) as an intraoperative triage screening tool to detect positive mucosal margins of the resected specimens of oral squamous cell carcinoma (OSCC) and serve as a guide for FS sampling.
Methods
Surgical samples of 30 consecutive patients with biopsy-proven OSCC were included in the study. A total of 140 mucosal margins were analyzed intraoperatively by TB and FS, the results were compared with the final histopathology.
Results
Of the 140 examined mucosal tumor margins, 14 stained positives with TB, six were true-positives, eight were false-positives, and there were no false-negatives, as confirmed by final histopathology of the same margins. The diagnostic performance measures were sensitivity 100.0%; specificity 94.0%; positive predictive value (PPV) 42.9%; negative predictive value (NPV) 100.0%; and accuracy 94.3% (95% CI: 89.0–97.5%). For FS, there were three true-positives, three false-negatives, and no false-positives. The diagnostic performance measures were sensitivity 50.0%; specificity 100.0%; PPV 100.0%; NPV 97.8%; and accuracy 97.9% (95% CI: 93.9–99.6%).
Conclusion
TB is less specific but more sensitive than FS for detecting positive mucosal margins of resected OSCC. Screening the tumor mucosal margins with TB before FS sampling may help identify more tumor-bearing margins.
Trial registration
This trial was registered at ClinicalTrials.gov. Registration number: NCT03554967. Registration date: June 13, 2018.
Publisher
Springer Science and Business Media LLC
Subject
Cancer Research,Genetics,Oncology
Cited by
9 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献