Author:
Zhang Jiarui,Chen Wenzhao,Weng Rui,Liang De,Jiang Xiaobing,Lin Hongheng
Abstract
Abstract
Background
Intermediate vertebral collapse is a newly discovered complication of consecutive two-level anterior cervical discectomy and fusion (ACDF). There have been no analytical studies related to the effects of endplate defects on the biomechanics of the intermediate vertebral bone after ACDF. This study aimed to compare the effects of endplate defects on the intermediate vertebral bone biomechanics in the zero-profile (ZP) and cage-and-plate (CP) methods of consecutive 2-level ACDF and to determine whether collapse of the intermediate vertebra is more likely to occur using ZP.
Methods
A three-dimensional finite element (FE) model of the intact cervical spine (C2–T1) was constructed and validated. The intact FE model was then modified to build ACDF models and imitate the situation of endplate injury, establishing two groups of models (ZP, IM-ZP and CP, IM-ZP). We simulated cervical motion, such as flexion, extension, lateral bending and axial rotation, and compared the range of motion (ROM), upper and lower endplate stress, fusion fixation device stress, C5 vertebral body stress, intervertebral disc internal pressure (intradiscal pressure, or IDP) and the ROM of adjacent segments in the models.
Results
There was no significant difference between the IM-CP model and the CP model in the ROM of the surgical segment, upper and lower endplate stress, fusion fixation device stress, C5 vertebral body stress, IDP, or ROM of the adjacent segments. Compared with the CP model, the endplate stress of the ZP model is significantly higher in the flexion, extension, lateral bending and axial rotation conditions. Compared with the ZP model, endplate stress, screw stress, C5 vertebral stress and IDP in IM-ZP were significantly increased under flexion, extension, lateral bending and axial rotation conditions.
Conclusions
Compared to consecutive 2-level ACDF using CP, collapse of the intermediate vertebra is more likely to occur using ZP due to its mechanical characteristics. Intraoperative endplate defects of the anterior lower margin of the middle vertebra are a risk factor leading to collapse of the middle vertebra after consecutive 2-level ACDF using ZP.
Publisher
Springer Science and Business Media LLC
Subject
Orthopedics and Sports Medicine,Rheumatology