Outcomes of occipitocervical fixation using a spinous process screw in C2 as a third anchor point for occipitocervical fixation: a case presentation

Author:

Liu Guanyi,Li Qing,Sheng Feng,Xu Nanjian,Li Ming,Wang Yang,Ma Weihu

Abstract

Abstract Background Posterior occipitocervical fixation and fusion are often required to address occipitocervical instability. Safe, stable internal fixation with screws is vital for the success of such surgery. Thus, poor selection of an internal fixation technique may cause fixation and fusion failure, possibly leading to neurovascular injury. Hence, in certain cases, such as in patients with severe instability of an occipitocervical deformity or osteoporosis, we hypothesized that having a third anchor point (a screw in C2) could enhance the stability of the occipitocervical fixation. Case presentation A 31-year-old man with occipitocervical deformity and spinal cord edema underwent a traditional occipitocervical fixation procedure but with the addition of a spinous process screw in C2 as a third anchor point. The procedure included posterior internal fixation and fusion. The occipitocervical fixation was completed by inserting occipital screws, bilateral C2 pedicle screws, C3 lateral mass screws, and a spinous process screw in C2 as a third anchor point. There were no neurovascular complications or incision-site infections. Postoperatively, radiography and computed tomography showed that the occipitocervical reduction and internal fixation had resulted in good spinal alignment, and magnetic resonance imaging showed no obvious spinal cord compression. At 4 months after the surgery, fusion was observed, and the occipitocervical screws remained well positioned. The patient continued to be monitored for 24 months postoperatively. At the 24-month follow-up visit, the muscle strength of the limbs was grade 5, and the patient’s sensation function had improved over his preoperative condition. Conclusions Use of a C2 spinous process screw as a third anchor point may enhance the stability of occipitocervical fixation. Further biomechanical and clinical studies are needed to validate this result.

Funder

the Ningbo Nature Fund

the Zhejiang public welfare Technology Project

Zhejiang Medical and Health Science and Technology Project

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,Rheumatology

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3