Noise after total knee arthroplasty has limited effect on joint awareness and patient-reported clinical outcomes: retrospective study

Author:

Taniguchi Hiroto,Itoh Masafumi,Yoshimoto Nobuyuki,Itou Junya,Kuwashima Umito,Okazaki KenORCID

Abstract

Abstract Background Some patients complain of noise after total knee arthroplasty (TKA). Controversy still exists on how the noise affects the clinical outcomes, including joint awareness, after TKA. The Forgotten Joint Score—12 (FJS-12) measures the clinical outcomes focusing on joint awareness after surgery. The Knee Society Scoring System—2011 (KSS-2011) includes questionnaires for satisfaction, expectation, and functional activities. The aim of this study is to clarify the relationship among FJS-12, KSS-2011, and the noise. Furthermore, the relationship between FJS-12 and KSS-2011 was validated. Methods Using FJS-12 and KSS-2011, 295 knees from 225 patients who underwent TKA were retrospectively evaluated. Noise perception was evaluated by a questionnaire with five grades, a method that follows the questionnaire form of FJS-12 (“Are you aware of the noise of your artificial joint?”; never, almost never, seldom, sometimes, mostly). Correlations among FJS-12, KSS-2011, and noise were analyzed. The patients were divided into four groups based on the mechanism of their implant [cruciate retaining, posterior stabilized, cruciate sacrificed, and bicruciate stabilized (BCS)]. FJS-12, KSS-2011, and noise were compared among the groups. Results A strong correlation was found between FJS-12 and total score of KSS-2011 (0.70; P < 0.001). FJS-12 correlated with KSS-2011 subcategories of “symptoms,” “satisfaction,” and “standard activities,” with correlation coefficients at approximately 0.60. Noise had weak correlations with FJS-12 (0.28; P < 0.001) and KSS-2011 (0.20 P < 0.001). In comparing the TKA mechanisms, BCS had remarkably better KSS-2011 and greater movement range but worse noise scores. Conclusions Noise perception after TKA had limited effect on joint awareness and clinical outcomes. FJS-12 correlated strongly with KSS-2011 and associated with satisfaction, residual symptoms, and daily activities, as assessed by KSS-2011 subscores. Trial registration This study was approved by the Medical Ethical Committee of the Tokyo Women’s Medical University (approval number: 4681 on March 2, 2018).

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,Rheumatology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3