Accuracy of fluoroscopic examination in the treatment of Bennett’s fracture

Author:

Yin Yaobin,Wang Yanqing,Wang Zhilong,Qu Wenrui,Tian Wen,Chen ShanlinORCID

Abstract

Abstract Background Restoration of joint congruity is an important factor for the prevention of subsequent arthritis in patients with Bennett’s fracture. Surgical treatment of Bennett’s fracture is thus generally recommended for displaced intra-articular fractures to the proximal aspect of the thumb metacarpal. Fluoroscopic examination is used to evaluate the adequacy of closed reduction after pinning of Bennett’s fracture. The purpose of this study was to determine the accuracy of fluoroscopy to determine the reduction of Bennett’s fractures. Methods A model was created, to mimic a Bennett’s fracture utilizing ten fresh-frozen cadaveric hands. An oblique cut was made in the proximal aspect of the thumb metacarpal using an oscillating saw. The small oblique fragment involved 1/4–1/3 of the joint surface was then shifted in position creating a step-off or gap at the fracture site. An anatomical reduction model, gap models (1 mm, 2 mm, 3 mm), and step-off models (1 mm, 2 mm, 3 mm) were created using percutaneous fixation with two 1.0 mm Kirschner wires for each cadaveric hand. Fluoroscopic assessment then took place and was reviewed by 2 attending hand surgeons blinded to the actual position. Their estimated fluoroscopic position was then compared to the actual displacement. Results The step-off and gap on fluoroscopic examination showed a significant difference compared to the step-off and gap from direct visualization. The frequency of underestimation for the 3 mm displacement models from the fluoroscopic examination was 60%. The frequency for overestimated was 9% for the models in which displacement was within 2 mm (0, 1, 2 mm). Conclusions The assessment of articular gap and step-off using PA (postero-anterior), AP (antero-posterior), and lateral view of fluoroscopic examination is not accurate as compared to the examination by direct visualization. Surgeons need to be aware that PA, AP and lateral view of fluoroscopic examination alone may not be sufficient to judge the final position of a reduced Bennett’s fracture. Other methods such as live fluoroscopy in multiple different planes, 3-dimensional fluoroscopy or arthroscopic examination should be considered.

Funder

Beijing Ji Shui Tan Hospital Nova Program

Natural Science Foundation of Beijing Municipality

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,Rheumatology

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3