The effect of surgeon-controlled variables on construct stiffness in lateral locked plating of distal femoral fractures

Author:

Weaver Michael J.,Chaus George W.,Masoudi Aidin,Momenzadeh Kaveh,Mohamadi Amin,Rodriguez Edward K,Vrahas Mark S.,Nazarian Ara

Abstract

Abstract Background Nonunion following treatment of supracondylar femur fractures with lateral locked plates (LLP) has been reported to be as high as 21 %. Implant related and surgeon-controlled variables have been postulated to contribute to nonunion by modulating fracture-fixation construct stiffness. The purpose of this study is to evaluate the effect of surgeon-controlled factors on stiffness when treating supracondylar femur fractures with LLPs: Does plate length affect construct stiffness given the same plate material, fracture working length and type of screws? Does screw type (bicortical locking versus bicortical nonlocking or unicortical locking) and number of screws affect construct stiffness given the same material, fracture working length, and plate length? Does fracture working length affect construct stiffness given the same plate material, length and type of screws? Does plate material (titanium versus stainless steel) affect construct stiffness given the same fracture working length, plate length, type and number of screws? Methods Mechanical study of simulated supracondylar femur fractures treated with LLPs of varying lengths, screw types, fractureworking lenghts, and plate/screw material. Overall construct stiffness was evaluated using an Instron hydraulic testing apparatus. Results Stiffness was 15 % higher comparing 13-hole to the 5-hole plates (995 N/mm849N vs. /mm, p = 0.003). The use of bicortical nonlocking screws decreased overall construct stiffness by 18 % compared to bicortical locking screws (808 N/mm vs. 995 N/mm, p = 0.0001). The type of screw (unicortical locking vs. bicortical locking) and the number of screws in the diaphysis (3 vs. 10) did not appear to significantly influence construct stiffness (p = 0.76, p = 0.24). Similarly, fracture working length (5.4 cm vs. 9.4 cm, p = 0.24), and implant type (titanium vs. stainless steel, p = 0.12) did also not appear to effect stiffness. Discussion Using shorter plates and using bicortical nonlocking screws (vs. bicortical locking screws) reduced overall construct stiffness. Using more screws, using unicortical locking screws, increasing fracture working length and varying plate material (titanium vs. stainless steel) does not appear to significantly alter construct stiffness. Surgeons can adjust plate length and screw types to affect overall fracture-fixation construct stiffness; however, the optimal stiffness to promote healing remains unknown.

Funder

AO North America

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,Rheumatology

Cited by 10 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3