Cementless curved endoprosthesis stem for distal femoral reconstruction in a Chinese population: a combined anatomical & biomechanical study

Author:

Hu Xin,Lu Minxun,Wang Yitian,Wen Yang,Tan Linyun,Du Guifeng,Zhou Yong,Luo Yi,Min Li,Tu Chongqi

Abstract

Abstract Background The endoprosthetic knee reconstruction using a current universal femoral stem might not be suitable for local population due to the anatomical difference between Chinese and Western populations. We measured the anatomical parameters of Chinese femurs as reference for stem design, and proposed a cementless, curved, short endoprosthesis stem for the reconstruction of distal femur. This study analyzed the biomechanical performance of the newly designed stem aimed at the identification of better operative strategy. Methods The CT–scanning data of femurs derived from 96 healthy Chinese volunteers were imported into the Mimics software, and a segmental measurement strategy was applied to evaluate the radius of curvature (ROC) of the femoral medullary cavity. Then, 4 kinds of endoprosthetic replacement models were created based on the measurement results. Model A: the distal tumor resected femora + straight stem A; Model B: the distal tumor resected femora + curved stem B; Model C: the distal tumor resected femora + curved stem C; Model D: the distal tumor resected femora + curved stem D. Finally, the mechanical difference among these models were compared by finite element analysis. Results The mean femoral ROC of Segment1, 2, 3, 4, 5 measured in the present study was 724.5 mm, 747.5 mm, 1016.5 mm, 1286.5 mm, and 1128 mm, respectively. Based on the femoral ROC of Segment2, the stem ROC of the curved stem B, C, and D was designed as 475 mm, 700 mm, and 1300 mm, respectively. Generally, all endoprosthetic replacement models showed a normal–like stress distribution on the femurs. However, compared to the straight stem, the biomimetic curved stem showed better biomechanical performance both in terms of reducing the extent of the stress shielding of the femur and in terms of minimizing the stress distribution of the implant. Conclusions The uncemented, curved, short stem with suitable ROC can perfectly match the Chinese femoral canal morphology which has better mechanical properties than the conventional femoral stem. Thus, this newly designed femoral stem might be an optimized method for treatment of malignant femoral tumours in the Chinese populations in the case that the numerical results are supported by future experimental studies.

Funder

the Fundamental Research Funds for the Central Universities

Chengdu science and technology project

8122 Project, Qingdao Research Institute of Sichuan University

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,Rheumatology

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Influence of Material, Design, and Loading on the Biomechanical Behavior of Femoral Stems: A Comparative FEM Study;2023 30th National and 8th International Iranian Conference on Biomedical Engineering (ICBME);2023-11-30

2. Three-dimensional design custom-made uncemented stem for revision of cemented distal femoral endoprosthesis due to aseptic loosening;Journal of Orthopaedic Surgery and Research;2023-07-17

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3