Effects of a 1-mm difference in bearing thickness on intraoperative bearing movement and kinematics in Oxford unicompartmental knee arthroplasty

Author:

Kawaguchi Kohei,Inui Hiroshi,Taketomi Shuji,Yamagami Ryota,Kono Kenichi,Sameshima Shin,Kage Tomofumi,Tanaka Sakae

Abstract

Abstract Background The choice of mobile bearing (MB) thickness is essential for obtaining successful results after mobile-bearing Oxford unicompartmental knee arthroplasty (UKA). This study aimed to investigate the effects of a 1-mm difference in bearing thickness on intraoperative MB movement and intraoperative knee kinematics in Oxford UKAs. Methods We prospectively investigated the effects of a 1-mm difference in bearing thickness on intraoperative MB movement and knee kinematics in 25 patients who underwent Oxford UKAs when surgeons didn’t know which bearing thickness to choose with 1-mm difference. A trial tibial component that was scaled every 2 mm was used to measure the intraoperative MB movement, and the tibial internal rotation relative to the femur and the knee varus angle was simultaneously evaluated using the navigation system as the knee kinematics. We separately evaluated sets of two MB thicknesses with 1-mm differences, and we compared the intraoperative parameters at maximum extension; 30º, 45º, 60º, and 90º flexion; and maximum flexion between the thicker MB (thick group) and the thinner MB (thin group). Results The MB in the thin group was located significantly posteriorly at 90º flexion compared with that in the thick group; however, there were no differences at the other flexion angles. There was significantly less tibial internal rotation in the thin group at 90º flexion than that in the thick group; however, there were no differences at the other flexion angles. The knee varus angles in the thick group were significantly smaller than those in the thin group by approximately one degree at all angles other than at 30º and 45º flexion. Conclusion The thicker MB could bring the less posterior MB movement and the more tibial internal rotation at 90º flexion, additionally the valgus correction angle in the thicker MB should be paid attention. These results could help surgeons to decide the thickness of MBs when they wonder the thickness of MB.

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,Rheumatology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3