Modified Kirschner wire percutaneous rotation prying reduction combined with elastic stable intramedullary nailing in children with Judet IV radial neck fracture

Author:

Fan YongFei,Xu WenQiang,Liu QiXin,Liu ChaoYu,Wang Wei

Abstract

Abstract Purpose This study was to investigate the feasibility and treatment effect of using modified Kirschner wire (K-wire) percutaneous rotation prying reduction combined with Elastic Stable Intramedullary Nailing (ESIN) in children with Judet IV radial neck fracture. Methods A retrospective analysis was conducted on 47 children with Judet IV radial neck fracture who underwent treatment with modified K-wire percutaneous rotation prying reduction combined with ESIN from April 2019 to November 2022, including 25 males and 22 females, with an average age of 8.79 years old (ranging from 5 to 14). The study recorded the surgical time, fluoroscopy time, reduction time, and reduction quality evaluated according to the Metaizeau radiological standard. During the last follow-up, the flexion-extension and forearm rotation function of the affected and healthy sides were recorded, and the Mayo Elbow Performance index was used to evaluate the elbow joint function. Results The average duration of the operation was 25.51 min (ranging from 14 to 43 min), with a mode of 2 reset times (ranging from 1 to 5) and 8 fluoroscopic times (ranging from 4 to 15). Based on the Metaizeau radiological standard for assessing reduction quality, 45 cases were deemed excellent, while 2 cases were considered good. Following 3–4 weeks of postoperative long-arm cast immobilization, exercises were performed to promote elbow joint and forearm rotation. The ESIN was removed after satisfactory fracture healing around 4 months postoperatively. The average follow-up period was 26.79 months (ranging from 5 to 48). At the final follow-up, the range of motion for the affected limb in flexion, extension, pronation, and supination was (140.23 ± 4.80)°, (4.43 ± 3.98)°, (84.09 ± 4.97)°, and (83.83 ± 4.55)°, respectively. There was no statistically significant difference compared to the healthy side, which had a range of motion of (141.36 ± 3.27)°, (5.28 ± 2.25)°, (85.66 ± 3.20)°, and (84.98 ± 2.57)° (P > 0.05). According to the Mayo Elbow Performance index, 44 cases were rated as excellent and 1 case was considered good. Conclusion The modified K-wire percutaneous rotation prying reduction combined with ESIN is an effective treatment for severe radial neck fractures in children. This technique offers several advantages, including the ability to easily “capture” significantly displaced radial heads, achieve rapid and accurate reduction, and reduce radiation exposure.

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,Rheumatology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3