Local heat generation during screw insertion into diaphyseal bone: a biomechanical study on different conditions (e.g. screw type, material, mode of insertion)

Author:

Paul Berit,Frank Andre,Raschke Michael J.,Wähnert DirkORCID

Abstract

Abstract Background The implantation of screws is a standard procedure in musculoskeletal surgery. Heat can induce thermal osteonecrosis, damage the bone and lead to secondary problems like implant loosening and secondary fractures. The aim of this study was to investigate whether screw insertion generates temperatures that can cause osteonecrosis. Methods We measured the temperature of twenty human femur diaphysis in a total of 120 measurements, while screws of different material (stainless steel and titanium alloy) and different design (locking and cortex screw) were inserted in three different screwing modes (manual vs. machine screwing at full and reduced rotational speed) with 6 thermocouples (3 cis and 3 trans cortex). Each was placed at a depth of 2 mm with a distance of 1.5 mm from the outer surface of the screw. Results The screw design (cortical > locking), the site of measurement (trans-cortex > cis-cortex) and the type of screw insertion (hand insertion > machine insertion) have an influence on the increase in bone temperature. The screw material (steel > titanium), the site of measurement (trans-cortex > cis-cortex) and the type of screw insertion (machine insertion > hand insertion) have an influence on the time needed to cool below critical temperature values. The combination of the two parameters (maximum temperature and cooling time), which is particularly critical for osteonecrosis, is found only at the trans-cortex. Conclusion Inserting a screw hast the potential to increase the temperature of the surrounding bone tissue above critical values and therefore can induce osteonecrosis. The trans-cortex is the critical area for the development of temperatures above the osteonecrosis threshold, making effective cooling by irrigation difficult. It would be conceivable to cool the borehole with cold saline solution before inserting the screw or to cool the screw in cold saline solution. If possible, insertion by hand should be considered.

Funder

v. Bodelschwinghsche Stiftungen Bethel

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,Rheumatology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3