Cementless augmented versus cemented Dual Mobility cups: medium-term outcome of case series with a control group

Author:

Ebied Ayman,Ebied Ahmed Ali,Badr Ismail TawfeekORCID,Affara Mostafa,Marie Sameh

Abstract

Abstract Background Post-operative dislocation and reconstruction of acetabular defects are two challenging topics in revision Total Hip Arthroplasty (rTHA). Cemented Dual Mobility (DM) cups on top of Kerboull Cross and bone graft have been successfully employed to overcome these challenges. The cementless augmented DM cups were recently introduced. In this study medium term results of the augmented cementless DM Coptos cups are reported and compared to the established technique of cemented DM cups and Kerboull plate. Material and methods This is a retrospective analysis of data collected on patients who received rTHA using DM cups in the period between June 2015 and September 2020. Two groups of patients were identified. The first group received cementless augmented DM-cups (NOVAE® Coptos TH–SERF) (Coptos TH cup group). The second comparable group who had Kerboull ring (KE ring group) and cemented DM cups (NOVAE® STICK). Demographic data, surgical technique, functional and radiological outcome as well as complications during the follow-up visits are reported. Results Forty-two patients with a mean age at the time of revision 48.8 ± 13.6 years. 29 patients received Coptos TH DM-cup, while 13 patients had Bone Graft (BG), KE ring and cemented DM cups for acetabular reconstruction. Acetabular defects were Paprosky types IIB and IIC in 31 patients and IIIA and B in 11 patients. The follow-up was 52.8 ± 21 months (mean ± STD); and the mean Harris Hip Score (HHS) at last visit was 91 ± 5. Good stability of all cups was reported. Full integration of the impaction graft was observed in 94% of the Coptos and 92% of the KE groups. One of the Coptos cups was readjusted and one case of single dislocation was recorded in the KE group. None of the DM cups in both groups was revised or awaiting revision. Conclusion Coptos TH cups achieve similar results to the cemented DM on KE ring at the medium term but long term outcome remains to be seen.

Funder

Minufiya University

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,Rheumatology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3