Radiomics nomogram based on dual-energy spectral CT imaging to diagnose low bone mineral density

Author:

Yao Qianqian,Liu Mengke,Yuan Kemei,Xin Yue,Qiu Xiaoqian,Zheng Xiuzhu,Li Changqin,Duan Shaofeng,Qin Jian

Abstract

Abstract Background Osteoporosis is associated with a decrease of bone mineralized component as well as a increase of bone marrow fat. At present, there are few studies using radiomics nomogram based fat-water material decomposition (MD) images of dual-energy spectral CT as an evaluation method of abnormally low Bone Mineral Density (BMD). This study aims to establish and validate a radiomics nomogram based the fat-water imaging of dual-energy spectral CT in diagnosing low BMD. Methods Ninety-five patients who underwent dual-energy spectral CT included T11-L2 and dual x-ray absorptiometry (DXA) were collected. The patients were divided into two groups according to T-score, normal BMD(T ≥ -1) and abnormally low BMD (T < -1). Radiomic features were selected from fat-water imaging of the dual-energy spectral CT. Radscore was calculated by summing the selected features weighted by their coefficients. A nomogram combining the radiomics signature and significant clinical variables was built. The ROC curve was performed to evaluate the performance of the model. Finally, we used decision curve analysis (DCA) to evaluate the clinical usefulness of the model. Results Five radiomic features based on fat-water imaging of dual-energy spectral CT were constructed to distinguish abnormally low BMD from normal BMD, and its differential performance was high with an area under the curve (AUC) of 0.95 (95% CI, 0.89–1.00) in the training cohort and 0.97 (95% CI, 0.91–1.00) in the test cohort. The radiomics nomogram showed excellent differential ability with AUC of 0.96 (95%CI, 0.91–1.00) in the training cohort and 0.98 (95%CI, 0.93–1.00) in the test cohort, which performed better than the radiomics model and clinics model only. The DCA showed that the radiomics nomogram had a higher benefit in differentiating abnormally low BMD from normal BMD than the clinical model alone. Conclusion The radiomics nomogram incorporated radiomics features and clinical factor based the fat-water imaging of dual-energy spectral CT may serve as an efficient tool to identify abnormally low BMD from normal BMD well.

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,Rheumatology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3