Comparative evaluation of posterior percutaneous endoscopy cervical discectomy using a 3.7 mm endoscope and a 6.9 mm endoscope for cervical disc herniation: a retrospective comparative cohort study

Author:

Yu Tong,Wu Jiu-Ping,Zhang Jun,Yu Hai-Chi,Liu Qin-YiORCID

Abstract

Abstract Background Posterior percutaneous endoscopy cervical discectomy (p-PECD) is an effective strategy for the treatment of cervical diseases, with a working cannula ranging from 3.7 mm to 6.9 mm in diameter. However, to date, no studies have been performed to compare the clinical outcomes of the use of endoscopes with different diameters in cervical disc herniation (CDH) patients. The purpose of this study was to compare the clinical outcomes of patients with unilateral CDH treated with p-PECD using a 3.7 mm endoscope and a 6.9 mm endoscope. Methods From January 2016 to June 2018, a total of 28 consecutive patients with single-level CDH who received p-PECD using either the 3.7 mm or the 6.9 mm endoscope were enrolled. The clinical results, including the surgical duration, hospitalization, visual analog scale (VAS) score and modified MacNab criteria, were evaluated. Cervical fluoroscopy, CT, and MRI were also performed during follow-up. Results Tthere was a significant difference in regard to the average identification time of the “V” point (18.608 ± 3.7607 min vs. 11.256 ± 2.7161 min, p < 0.001) and the mean removal time of the overlying tissue (16.650 ± 4.1730 min vs. 12.712 ± 3.3079 min, p < 0.05) for the use of the 3.7 mm endoscope and the 6.9 mm endoscope, respectively. The postoperative VAS and MacNab scores of the two endoscopes were significantly improved compared with those the preoperative scores (p < 0.05). Conclusion The application of both the 3.7 mm endoscope and 6.9 mm endoscope represent an effective method for the treatment of CDH in selected patients, and no significant difference can be observed in the clinical outcomes of the endoscopes. The 6.9 mm endoscope shows superiority to the 3.7 mm endoscope in terms of the efficiency of “V” point identification, the removal of overlying soft tissue and the prevention of spinal cord injury. However, the 6.9 mm endoscope may be inferior to the 3.7 mm endoscope in regards to anterior foraminal decompression due to its large diameter; this result needs to be further evaluated with the support of a large number of randomized controlled trials.

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,Rheumatology

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3