Author:
Yang Yang,Jiang Lingjun,Zhou Xiaoxiao,Zhou Xiaobo,Chen Haixiao,Chen Zhongyi
Abstract
Abstract
Purpose
Robotic-assisted total knee arthroplasty (r-TKA) facilitates precise bone resection and lower limb alignment, yet accuracy and functional recovery for severe varus/valgus deformity is not well-documented. The aim of study was to investigate whether r-TKA improves implant alignment in the coronal and sagittal view and early functional recovery compared to conventional TKA(c-TKA).
Methods
This comparative study included 86 patients with symptomatic knee arthritis who underwent primary TKA at our institution between 1st May and 31th November 2021. Radiological parameters evaluated included hip-knee-ankle angle (HKAA), femoral varus-valgus angle (FVVA), tibial varus-valgus angle (TVVA), posterior tibial slope angle (PTSA), femoral sagittal angle (FSA), posterior condylar offset ratio, and Insall-Salvati index. Operative time, stay length, and complications were reviewed from patient records. The hospital for special surgery (HSS), Visual Analogue Scale (VAS) and knee joint motion range were evaluated at the six-month follow-up.
Results
The c-TKA and r-TKA groups had no significant differences in HKAA (179.73 ± 3.76°, range: 172.10-188.90° vs. 180.53 ± 2.91°, range: 173.30-188.32°, p = 0.277), FVVA (96.13 ± 2.61°, range: 90.27-101.52° vs. 96.38 ± 2.23°, range: 90.98-100.95°, p = 0.636), and TVVA (88.74 ± 2.03°, range: 83.75–92.74° vs. 89.43 ± 1.83°, range: 85.32–94.15°, p = 1.000). Outlier of mechanical alignment incidence (> 3°) was significantly lower in r-TKA compared with c-TKA, 17.50% (7/40) vs. 41.30% (19/46), (p = 0.017). PTSA of r-TKA remained significantly lower than c-TKA (p = 0.009) in mild-deformity patients. For severe varus/valgus deformity, r-TKA had a significantly lesser HKAA-outlier incidence (p = 0.025), PTSA-outlier incidence (p = 0.019), and lower PTSA (p < 0.001) compared with c-TKA. The r-TKA functional outcome was better than c-TKA regarding HSS (93.12 ± 1.97, range: 90–95, 95%CI:92.11–94.13 vs. 91.33 ± 2.50, range: 85–95, 95%CI:90.20-92.69, p = 0.036), and VAS (0.24 ± 0.44, range:0–1 vs. 0.72 ± 0.75, range:0–2, p = 0.026), knee joint flexion (118.53° ± 8.06, range: 105–130°, 95%CI:114.39-122.67° vs. 112.22 ± 8.09°, range: 100–130°, 95%CI:108.20-116.24° ,p = 0.027) for severe varus/valgus deformity.
Conclusion
r-TKA improved lower-limb coronal alignment, sagittal implant position, and early functional recovery for patients with severe varus/valgus deformity of the knee. r-TKA did not confer substantial advantages over c-TKA in both radiological and clinical outcomes for the mild varus/valgus deformity.
Funder
Taizhou City Science and Technology Program of Zhejiang Province
Science Foundation of Enze Medical Center
Pudong New Area Science and Technology Development Fund
Publisher
Springer Science and Business Media LLC
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
1. Robotic Total Knee Arthroplasty: An Update;Journal of Personalized Medicine;2024-05-30