Author:
Muench Lukas N.,Kia Cameron,Otto Alexander,Mehl Julian,Baldino Joshua B.,Cote Mark P.,McCarthy Mary Beth,Beitzel Knut,Mazzocca Augustus D.
Abstract
Abstract
Background
Low aspiration volumes have been recommended to allow for higher concentrations of progenitor cells during bone marrow harvesting. However, these guidelines then require multiple aspiration attempts in order to maximize cellular yield. The purpose of this study was to investigate the effect of a single, high-volume aspiration with four consecutive aliquots on the number of nucleated cells (NCs) and colony-forming units (CFUs) in concentrated bone marrow aspirate (cBMA) taken from the proximal humerus.
Methods
cBMA was taken from the proximal humerus of patients undergoing arthroscopic rotator cuff surgery. Four 12-mL double syringes were used consecutively from a single trocar to obtain four 10 cc aliquots. Each then underwent centrifugation to create a fractionated layer rich in nucleated cells. Following cellular separation, NCs were counted and CFUs were evaluated after incubation of 7–10 days. Cellular comparisons between each aliquot were performed along with their interaction with patient age and sex.
Results
Twenty-nine patients (55.9 ± 4.6 years) were included in this study. The number of NCs and CFUs showed significant differences between the four aliquots of aspirate, with the first 10 cc aliquot providing the highest amount (p < 0.001, respectively). No significant differences were found between the sum of the three sequential aliquots compared to the initial 10 cc sample. There were no significant differences between male and female patients (p > 0.05). Increasing age resulted in no significant decrease in the number of NCs and CFUs across the four consecutive aliquots (p > 0.05).
Conclusion
In conclusion, while the initial aliquot provided the greatest number of nucleated cells and cultured CFUs, the addition of each sequential volume aspirate yielded similar amounts in total. This demonstrates the potential effectiveness of obtaining of higher volume aspirates from the proximal humerus during rotator cuff repair.
Publisher
Springer Science and Business Media LLC
Subject
Orthopedics and Sports Medicine,Rheumatology
Cited by
6 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献