Clinical study on freehand of bicortical sacral screw fixation with the assistance of torque measurement device

Author:

Jiang Guozheng,Xu Luchun,Ma Yukun,Guan Jianbin,Feng Ningning,Qiu Ziye,Zhou Shibo,Li Wenhao,Yang Yongdong,Qu Yi,Zhao He,Li Zeyu,Yu Xing

Abstract

Abstract Background Sacral screw loosening is a typical complication after internal fixation surgery through the vertebral arch system. Bicortical fixation can successfully prevent screw loosening, and how improving the rate of bicortical fixation is a challenging clinical investigation. Objective To investigate the feasibility of improving the double corticality of sacral screws and the optimal fixation depth to achieve double cortical fixation by combining the torque measurement method with bare hands. Methods Ninety-seven cases of posterior lumbar internal fixation with pedicle root system were included in this study. Based on the tactile feedback of the surgeon indicating the expected penetration of the screw into the contralateral cortex of the sacrum, the screws were further rotated by 180°, 360°, or 720°, categorized into the bicortical 180° group, bicortical 360° group, and bicortical 720° group, respectively. Intraoperatively, the torque during screw insertion was recorded. Postoperatively, the rate of double-cortex engagement was evaluated at 7 days, and screw loosening was assessed at 1 year follow-up. Results The bicortical rates of the 180° group, 360° group, and 720° group were 66.13%, 91.18% and 93.75%, respectively. There were statistically significant differences between the 180° group and both the 360° and 720° groups (P < 0.05). However, there was no statistically significant difference between the 360° group and the 720° group (P > 0.05).The rates of loosening of sacral screws in the 180° group, 360° group, and 720° group were 20.97%, 7.35% and 7.81%, respectively. There were statistically significant differences between the 180° group and both the 360° and 720° groups (P < 0.05). However, there was no statistically significant difference between the 360° group and the 720° group (P > 0.05). The bicortical 360° group achieved a relatively satisfactory rate of dual cortical purchase while maintaining a lower rate of screw loosening. Conclusion Manual insertion of sacral screws with the assistance of a torque measurement device can achieve a relatively satisfactory dual cortical purchase rate while reducing patient hospitalization costs.

Publisher

Springer Science and Business Media LLC

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3