Author:
Zhou Xiaoji,Zhou Jiangshan,Qian Huajun,Qian Chunxiao,Xu Bin,Pan Lv,Chu Xudong
Abstract
Abstract
Background
There are many difficulties in the reduction and fixation of the tibial plateau fractures involving posterolateral quadrant using general plates via traditional approaches. By imaging the area above the fibulae capitulum, this study was performed to investigate the feasibility of the trans-fibular-head approach and to design an ideal anatomical plate.
Methods
MRI and CT scans of the knee joint were collected from 205 healthy volunteers (103 males, 102 females). Gender and height were used to divide the volunteers into groups separately: (1) A1 group and A2 group according to gender, (2) B1 group and B2 group according to height. Based on the images, several parameters were defined and measured to describe the space above the head of the fibula. In addition, differences in these parameters between genders and height were compared.
Results
The narrowest distance in the bony region was (10.96 ± 1.39) mm, (5.41 ± 0.97 mm) in the bone-ligament region. The narrowest distance of bony region in the A1 group was more than that in the A2 group (11.21 ± 1.62 mm, 10.85 ± 1.47 mm, p = 0.029). The narrowest distance of the bony region was (10.21 ± 1.42) mm and (11.65 ± 1.39) mm in the B1 group and B2 group, respectively (p = 0.002). The narrowest distance of the bone-ligament region was (5.39 ± 0.78) mm and (5.22 ± 1.21) mm in the A1 group and A2 group, respectively. No statistically significant differences were observed between the A1 group and the A2 group in terms of the narrowest distance of the bone-ligament region. In the B1 group, the narrowest distance of the bone-ligament region (5.18 ± 0.71 mm) was not significantly less than that (5.31 ± 0.91 mm) in the B2 group.
Conclusion
The space above the fibular capitellum was ample enough to place the plate for treating tibial plateau fractures involving posterolateral quadrant. The divisions of the lateral tibial plateau by 3-dimensional CT and the parameters of each region were crucial for providing guidance for designing the anatomical plate for the trans-fibular-head approach.
Funder
Wuxi Municipal Bureau on Science and Technology
Science and Technology Plan of Wuxi Municipal Health Commission Funds
Publisher
Springer Science and Business Media LLC