Elliptical and spherical heads show similar obligate glenohumeral translation during axial rotation in total shoulder arthroplasty

Author:

Muench Lukas N.,Murphey Matthew,Oei Bridget,Kia Cameron,Obopilwe Elifho,Cote Mark P.,Mazzocca Augustus D.,Berthold Daniel P.

Abstract

Abstract Background Elliptical shape humeral head prostheses have been recently proposed to reflect a more anatomic shoulder replacement. However, its effect on obligate glenohumeral translation during axial rotation compared to a standard spherical head is still not well understood. The purpose of the study was to compare obligate humeral translation during axial rotation using spherical and elliptical shaped humeral head prostheses. It was hypothesized that the spherical head design would show significantly more obligate translation when compared to the elliptical design. Methods Six fresh-frozen cadaveric shoulders were utilized for biomechanical testing of internal (IR) and external (ER) rotation at various levels of abduction (0°, 30°, 45°, 60°) with lines of pull along each of the rotator cuff muscles. Each specimen underwent the following three conditions: (1) native; total shoulder arthroplasty (TSA) using (2) an elliptical and (3) spherical humeral head implant. Obligate translation during IR and ER was quantified using a 3-dimensional digitizer. The radius of curvature of the superoinferior and anteroposterior dimensions of the implants was calculated across each condition. Results Posterior and inferior translation as well as compound motion of spherical and elliptical heads during ER was similar at all abduction angles (P > 0.05, respectively). Compared to the native humeral head, both implants demonstrated significantly decreased posterior translation at 45° (elliptical: P = 0.003; spherical: P = 0.004) and 60° of abduction (elliptical: P < 0.001; spherical: P < 0.001). During internal rotation at 0° abduction, the spherical head showed significantly more compound motion (P = 0.042) compared to the elliptical head. The spherical implant also demonstrated increased anterior translation and compound motion during internal rotation at 60° abduction (P < 0.001) compared to the resting state. This difference was not significant for the native or elliptical head design at this angle (P > 0.05). Conclusion In the setting of TSA, elliptical and spherical head implants showed similar obligate translation and overall compound motion during axial rotation. A gained understanding of the consequences of implant head shape in TSA may guide future surgical implant choice for better recreation of native shoulder kinematics and potentially improved patient outcomes. Level of evidence Controlled Laboratory Study.

Funder

Technische Universität München

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,Rheumatology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3