18F-FDG and 68 Ga-FAPI PET/CT for the evaluation of periprosthetic joint infection and aseptic loosening in rabbit models

Author:

Wang Yiqun,Li Yu,Han Liang,Wang Jun,Zhang Cong,Qi Erpeng,Zhang Dongyun,Zhang Xiaojun,Huan Yong,Tian Jiahe

Abstract

Abstract Purpose We built a joint replacement loosening model based on the original rabbit model of infection and evaluated the performance characteristics of 18F-FDG and 68 Ga-FAPI in evaluating infection and loosening. Methods After surgery, the rabbits were divided into four groups, with six individuals in the control group and 10 each in the aseptic loosening, S. aureus and S. epidermidis groups. PET/CT and serological examination were performed three times at two-week intervals. After the rabbits were euthanized, micro-CT, tissue pathology, pullout tests and scanning electron microscopy (SEM) were performed. Results The pullout test and SEM showed the feasibility of the aseptic loosening model. 18F-FDG showed similar performance in the control and loosening groups. The SUVmax of the S. aureus group was consistently higher than that of the S. epidermidis group. As for 68 Ga-FAPI, the SUVmax of the control group was lowest in the second week and gradually increased over subsequent weeks. The SUVmax of the loosening group began to exceed that of the control group after the second week. The SUVmax of the S. aureus group in the second week was the lowest among the four groups and increased as the number of weeks increased. The pathology results showed concordance with the performance of PET/CT. Linear regressions between SUVmax and serology showed that 18F-FDG was positively correlated with CRP and IL-6, while 68 Ga-FAPI revealed negative correlations with CRP and IL-6 in the second week and positive correlations in the sixth week. In addition, the SUVmax and MT(target)V of both 18F-FDG and 68 Ga-FAPI were negatively correlated with bone volume/trabecular volume (TV) and bone surface area/TV. Conclusion In this longitudinal observation, 68 Ga-FAPI showed greater sensitivity than 18F-FDG in detecting diseases, and 68 Ga-FAPI had no intestinal or muscular uptake. The MT(target)V of 68 Ga-FAPI was larger than that of 18F-FDG, which meant that 68 Ga-FAPI had the potential to define the scope of lesions more accurately. Finally, the SUVmax of 68 Ga-FAPI could not differentiate between loosening and infection; further study of the diagnostic criteria is warranted.

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,Rheumatology

Cited by 7 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3