Background
The aim of the study is to assess the diagnostic value of preoperative conventional radiographs for diagnosing infection associated with internal fixation devices.
Methods
We prospectively collected data of patients undergoing removal of internal fixation devices for any reason. Infection was diagnosed in case of purulence, sinus tract, positive histopathology and/or positive peri-implant tissue or sonication fluid culture. In radiographs radiolucent lines, implant breakage or displacement, or periosteal reaction were assessed. White blood cell count (WBC) and serum C-reactive protein (CRP) were determined at admission.
Results
We included 421 surgeries in 380 patients (median age 53.6 years, range 11–98 years), mainly indicated for infection (24.9%), nonunion (20.0%) and symptomatic implants (13.5%). Radiologic signs of infection included radiolucent lines (11.4%); implant breakage (12.4%) or displacement (10.7%); and periosteal reaction (7.1%). Infection was confirmed in 116 cases (27.6%). Only radiolucent lines (OR = 1.86 [95%CI: 1.00–3.38]) and periosteal reaction (OR = 2.48 [95%CI: 1.17–5.26]) were associated with infection, with a low sensitivity (16.4 and 12.1%, respectively), and high specificity (90.5 and 94.8%, respectively). Preoperative WBC and CRP had a sensitivity of 23.0 and 35.3%, and specificity of 91.7 and 89.5%, respectively.
Conclusions
Radiological signs suggestive of infection were uncommon. Radiolucency and periosteal reaction were associated with infection, though with low sensitivity.
Publisher
Springer Science and Business Media LLC
Subject
Orthopedics and Sports Medicine,Rheumatology
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献