Analysis of measurement changes in pelvic incidence according to pelvic rotation using a three-dimensional model

Author:

Lee Ki Young,Lee Jung-Hee,Im Sang-Kyu,Lee Won Young

Abstract

Abstract Background Pelvic incidence (PI) is used as a key parameter in surgical correction of adult spinal deformity (ASD). However, reflecting the exact center or inclination of the three-dimensional anatomical structures on the two-dimensional (2D) sagittal radiographs is limited, resulting in measurement errors. Therefore, we evaluated whether there is a change in PI measurement according to the actual rotation of the pelvis, and conducted a study on a more accurate method for PI measurement using 2D sagittal radiographs. Methods From 2014 to 2015, the data of 30 patients who visited our outpatient clinic were analyzed retrospectively. CT scans including those of the lower lumbar spine, pelvis, and both femurs in the DICOM format were imported to Mimics Research 17.0 (Materialise NV, Belgium), SolidWorks (Dassault systems, France), and AutoCAD 2014 (AUTODESK, US). The changes in PI according to vertical and horizontal pelvic rotations were evaluated. Results The average PIs according to the horizontal pelvic rotations measured on AutoCAD with 0°, 5°, 10°, 15°, 20°, 25°, 30°, 35°, and 40° were 48.8°, 48.7°, 48.3°, 47.8°, 46.9°, 45.6°, 44.0°, 42.2°, and 39.9°, respectively. The PI with an acceptable error of 6° on radiographs was 35° in the horizontal pelvic rotation. The average PIs according to the vertical pelvic rotations measured on AutoCAD with 0°, 5°, 10°, 15°, 20°, 25°, 30°, 35°, and 40° were 48.8°, 49.0°, 49.5°, 50.2°, 51.3°, 52.7°, 54.4°, 56.6°, and 59.4°, respectively. The PI with an acceptable error of 6° on radiographs was 30° in the vertical pelvic rotation. Conclusions This study revealed that the PI value could differ from the actual anatomical value due to the horizontal and vertical rotation of the pelvis while acquiring the radiograph. Regarding whole-spine lateral radiographs, errors in PI measurement may occur due to pelvic rotation or nonvertical projection of X-rays. In the standing pelvic lateral radiographs, ensuring superposition of the femoral heads at the center and obtaining the straight sacral endplate by referring to CT or magnetic resonance imaging would be a more accurate measurement method to define PI.

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,Rheumatology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3