Can ultrasound-guided radiofrequency ablation of genicular nerves of the knee, be performed without locating corresponding arterial pulsations—a cadaveric study

Author:

Kolakkanni Chinchu,Gonnade Nitesh Manohar,Gaur Ravi,Nayyar Ashish Kumar,Ghuleliya Rambeer,TK Abins

Abstract

Abstract Introduction Given the rising prevalence of knee osteoarthritis, radiofrequency ablation of genicular nerves (RFA) has emerged as a promising treatment option for knee pain. The knee has an extremely complex and variable innervation with nearly 13 genicular nerves described. The frequently ablated genicular nerves are the superomedial (SMGN), the superolateral (SLGN), and the inferomedial (IMGN) genicular nerves. Conventionally, under ultrasound guidance, these nerves are ablated near the corresponding arterial pulsations, but due to the rich vascular anastomosis around the knee joint, identifying the arteries corresponding to these constant genicular nerves can be tedious unless guided by some bony landmarks. In this study, we have evaluated whether it is possible to accurately target these three genicular nerves by just locating bony landmarks under ultrasound in human cadaveric knee specimens. Methods Fifteen formalin-fixed cadaveric knee specimens were studied. SMGN was targeted 1 cm anterior to the adductor tubercle in the axial view. For SLGN, in the coronal view, the junction of the lateral femoral condyle and shaft was identified, and at the same level in the axial view, the crest between the lateral and posterior femoral cortex was targeted. For IMGN in the coronal view, the midpoint between the most prominent part of the medial tibial condyle and the insertion of the deep fibers of the medial collateral ligament was marked. The medial end of the medial tibial cortex was then targeted at the same level in the axial view. The needle was inserted from anterior to posterior, with an in-plane approach for all nerves. Eosin, 2% W/V, in 0.1 ml was injected. Microdissection was done while keeping the needle in situ. Staining of the nerve was considered a positive outcome, and the percentage was calculated. The nerve-to-needle distance was measured, and the mean with an interquartile range was calculated. Result The accuracies of ultrasound-guided bony landmarks of SMGN, SLGN, and IMGN were 100% in terms of staining, with average nerve-to-needle distances of 1.67, 3.2, and 1.8 mm respectively. Conclusion It is with 100% accuracy, that we can perform RFA of SMGN, SLGN, and IMGN under ultrasound guidance, by locating the aforementioned bony landmarks.

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,Rheumatology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3