Comparison between magnetic resonance imaging and electrical impedance myography for evaluating lumbar skeletal muscle composition

Author:

Albano DomenicoORCID,Gitto Salvatore,Vitale Jacopo,Bernareggi Susan,Aliprandi Alberto,Sconfienza Luca Maria,Messina Carmelo

Abstract

Abstract Background To compare electrical impedance myography (EIM) and MRI in assessing lumbar skeletal muscle composition. Methods One hundred forty-one patients (78 females, mean age 57 ± 19 years) were prospectively enrolled and underwent lumbar spine MRI, EIM with Skulpt®, and clinical evaluation including the questionnaire SARC-F. MRIs were reviewed to assess the Goutallier score of paravertebral muscles at L3 level and to calculate the cross sectional area (CSA) of both psoas, quadratus lumborum, erector spinae, and multifidus muscles on a single axial slice at L3 level, in order to calculate the skeletal muscle index (SMI=CSA/height2). We tested the correlation between EIM-derived parameters [body fat percentage (BF%) and muscle quality] and body mass index (BMI), Goutallier score (1–4), SMI, and SARC-F scores (0–10) using the Pearson correlation coefficient. The strength of association was considered large (0.5 to 1.0), medium (0.3 to 0.5), small (0.1 to 0.3). Results Pearson’s correlation coefficient showed small (0.26) but significant (p < 0.01) positive correlation between BF% obtained with EIM and Goutallier score. Small negative correlation (− 0.22, p < 0.01) was found between EIM muscle quality and Goutallier Score. Large negative correlation (− 0.56, p < 0.01) was found between SMI and Goutallier Score, while SMI showed small negative correlation with SARC-F (− 0.29, p < 0.01). Medium positive correlation was found between Goutallier Score and SARC-F (0.41, p < 0.01). BMI showed medium positive correlation with SMI (r = 0.369, p < 0.01) and small correlation with EIM muscle quality (r = − 0.291, p < 0.05) and BF% (r = 0.227, p < 0.05). We found a substantial increase of the strength of associations of BF% and muscle quality with Goutallier in the 18–40 years (r = 0.485 and r = − 0.401, respectively) and in the 41–70 years group (r = 0.448 and r = − 0.365, respectively). Conclusions Muscle quality and BF% measured by EIM device showed only small strength of correlation with other quantitative parameters for assessing muscle mass and fat infiltration. Interesting results have been found in younger patients, but Skulpt Chisel™ should be applied cautiously to assess lumbar skeletal muscle composition. This point deserves further investigation and other studies are warranted. Trial registration The registration number of this study is 107/INT/2019.

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,Rheumatology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3