Author:
Kawahara Shinya,Mawatari Taro,Matsui Gen,Hamai Satoshi,Akasaki Yukio,Tsushima Hidetoshi,Nakashima Yasuharu
Abstract
Abstract
Background
In performing primary constrained total knee arthroplasties (TKA) to imbalanced knees, the offset stem is sometimes compelled to use, although this is associated with surgical difficulties. We developed a modified procedure which might be able to fit the anteroposterior (AP) and mediolateral (ML) position of the femoral component simultaneously with the straight stem. Purposes of this study were to evaluate usefulness of the modified procedure both in computer simulations and actual surgeries.
Methods
We included 32 knees that had undergone primary TKA using constrained implants because of the coronal imbalance. In the component-first procedure, the distal femur was prepared to fit the AP and ML position of the femoral component simultaneously at first, as in primary TKA. Finally, the stem hole is created based on the femoral component position (the component-first procedure). The femoral component and extension stem were simulated using the three-dimensional planning software (ZedKnee) following the component-first procedure. We investigated the suitability of the straight stem through computer simulation and evaluation of actual surgeries. Clinical and radiographical outcomes were also evaluated at the latest follow-up.
Results
The component-first procedure enabled the AP and ML position of the femoral component to be fitted simultaneously with the straight stem in simulations and actual surgeries in all cases. The stem diameter was not significantly different between simulations and actual surgeries (13.9 and 13.7 mm on average, respectively, p = 0.479) and almost similar from intraclass correlation coefficient analysis (kappa value 0.790). Clinical and radiographical outcomes were almost similar to primary TKA cases and there was no case of component loosening, cortical bone hypertrophy around the stem and stem-tip pain.
Conclusions
Our improved surgical procedure may facilitate use of the constrained implant for more cases of primary TKA in imbalanced knees without the usual surgical difficulties.
Trial registration
Retrospectively registered.
Publisher
Springer Science and Business Media LLC
Subject
Orthopedics and Sports Medicine,Rheumatology
Reference29 articles.
1. American Joint Replacement Registry (AJRR) Annual Report 2019 (https://www.aaos.org/registries/publications/ajrr-annual-report/)
2. Lombardi AV, Berend KR, Adams JB. Why knee replacements fail in 2013: patient, surgeon, or implant? Bone Joint J. 2014;96(11):101–4.
3. Swedish Knee Arthroplasty Register Annual Report 2019 (https://www.researchgate.net/publication/338541305_The_Swedish_Knee_Arthroplasty_Register_-_Annual_report_2019)
4. Thiele K, Perka C, Matziolis G, Mayr HO, Sostheim M, Hube R. Current failure mechanisms after knee arthroplasty have changed: polyethylene wear is less common in revision surgery. J Bone Joint Surg Am. 2015;97(9):715–20.
5. Morgan H, Battista V, Leopold SS. Constraint in primary total knee arthroplasty. J Am Acad Orthop Surg. 2005;13(8):515–24.
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献