Changes in femoral rollback and rotation with increasing coupling in knee arthroplasty—a biomechanical in-vitro study

Author:

Lorenz Andrea,Winter Alexander,Mederake Moritz,Freidhager Clemens,Hofmann Ulf Krister,Leichtle Ulf Gunther

Abstract

Abstract Background After total knee arthroplasty, 10–30% of patients still complain about knee pain, even after exact positioning of the components. Altered knee kinematics are crucial in this regard. The aim of our study was to experimentally determine the influence of different degrees of component coupling of knee prostheses on joint kinematics during muscle-loaded knee flexion in-vitro. Methods Femoral rollback and femoral rotation of a standard cruciate retaining (GCR), a posterior stabilized (GPS), a rotational hinge (RSL) and a total hinge (SSL) design of the same series of knee replacement implants (SL-series) of one single manufacturer (Waldemar Link GmbH, Hamburg, Germany) were analyzed and set in relation to the motion of the corresponding native knee in a paired study design. All different coupling degrees were analyzed in the same human knees. To simulate muscle loaded knee flexion, a knee simulator was used. Kinematics were measured with an ultrasonic motion capture system and integrated in a calculated coordinate system via CT-imaging. Results The largest posterior motion on the lateral side was found for the native knee (8.7 ± 7.0 mm), followed by the GPS (3.2 ± 5.1 mm) and GCR (2.8 ± 7.3 mm) implants, while no motion was found for the RSL (0.1 ± 3.0 mm) and the SSL (-0.6 ± 2.7 mm) implants. In contrast, on the medial side, only the native knee showed a posterior motion (2.1 ± 3.2 mm). Regarding femoral external rotation, the only implant where the observed difference did not reach statistical significance when compared to the native knee was the GCR (p = 0.007). Conclusion The GCR and GPS kinematics closely imitate those of the native joint. Medial femoral rollback is reduced, however, with the joint pivoting around a rotational center located in the medial plateau. Without additional rotational forces, the coupled RSL and SSL prostheses closely resemble each other with no femoral rollback or relevant rotational component. The femoral axis, however, shifts ventrally in both models when compared with their primary counterparts. The positioning of the coupling mechanism in the femoral and tibial component thus can already lead to altered joint kinematics even in prostheses with an identical surface geometry.

Funder

Universitätsklinikum Tübingen

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,Rheumatology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3