Which head element is more effective for cement augmentation of TFNA? Helical blade versus lag screw

Author:

Mitsuzawa SadakiORCID,Nakamata Takeharu,Mitamura Shogo,Yasuda Tadashi,Matsuda Shuichi

Abstract

Abstract Background Early fixation and rehabilitation is the gold standard treatment for intertrochanteric femur fractures. Cement augmentation through perforated head elements has been developed to avoid postoperative complications such as cut-out or cut-through. The purpose of this study was to compare two head elements in terms of cement distribution using computed tomography (CT) and to examine their initial fixation and clinical outcomes. Methods Elderly patients who had intertrochanteric fractures were treated with a trochanteric fixation nail advanced (TFNA) helical blade (Blade group) or a TFNA lag screw (Screw group). In both groups, 4.2 mL of cement was injected under an image intensifier (1.8 mL of cement was directed cranially and 0.8 mL each caudally, anteriorly, and posteriorly). Patient demographics and clinical outcome were investigated post-operatively. Cement distribution from the center of the head element was evaluated with CT. Maximum penetration depth (MPD) were measured in the coronal and sagittal planes. On each axial plane, the cross-sectional areas in the cranial, caudal, anterior and posterior directions were calculated. The sum of cross-sectional areas (successive 36 slices) was defined as the volume of the head element. Results The Blade group included 14 patients, and the Screw group included 15 patients. In the Blade group, MPD in the anterior and caudal direction was significantly greater than that in the posterior direction (p < 0.01). In the Screw group, volume in the cranial and posterior direction was significantly greater than that in the Blade group (p = 0.03). Subsequently, the total volume in the Screw group was significantly larger than that in the Blade group (p < 0.01). No significant correlation was detected between bone mineral density, T score, young adult mean, and total cement volume. Change in radiographic parameters and clinical outcome such as Parker score and visual analog scale were similar in both groups. No patients suffered from cut-out / cut through or non-union. Conclusions The position of cement distribution through the lag screw is different from that through the helical blade, and the total volume of the head element is significantly larger in the lag screw. Both groups had similarly effective results in terms of mechanical stability after surgery, postoperative pain and early phase of rehabilitation. Trial registration Current Controlled Trials ISRCTN45341843, 24/12/2022, Retrospectively registered.

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,Rheumatology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3