Abbreviated quantitative UTE imaging in anterior cruciate ligament reconstruction

Author:

Fukuda Takeshi,Wengler Kenneth,Tank Dharmesh,Korbin Seth,Paci James M.,Komatsu David E.,Paulus Megan,Huang Mingqian,Gould Elaine,Schweitzer Mark E.,He XiangORCID

Abstract

Abstract Background Existing ultrashort echo time magnetic resonance imaging (UTE MRI) methods require prohibitively long acquisition times (~ 20–40 min) to quantitatively assess the clinically relevant fast decay T2* component in ligaments and tendons. The purpose of this study was to evaluate the feasibility and clinical translatability of a novel abbreviated quantitative UTE MRI paradigm for monitoring graft remodeling after anterior cruciate ligament (ACL) reconstruction. Methods Eight patients who had Graftlink™ hamstring autograft reconstruction were recruited for this prospective study. A 3D double-echo UTE sequence at 3.0 Tesla was performed at 3- and 6-months post-surgery. An abbreviated UTE MRI paradigm was established based on numerical simulations and in vivo validation from healthy knees. This proposed approach was used to assess the T2* for fast decay component ($$ {T}_{2s}^{\ast } $$ T 2 s ) and bound water signal fraction (fbw) of ACL graft in regions of interest drawn by a radiologist. Results Compared to the conventional bi-exponential model, the abbreviated UTE MRI paradigm achieved low relative estimation bias for $$ {T}_{2s}^{\ast } $$ T 2 s and fbw over a range of clinically relevant values for ACL grafts. A decrease in $$ {T}_{2s}^{\ast } $$ T 2 s of the intra-articular graft was observed in 7 of the 8 ACL reconstruction patients from 3- to 6-months (− 0.11 ± 0.16 ms, P = 0.10). Increases in $$ {T}_{2s}^{\ast } $$ T 2 s and fbw from 3- to 6-months were observed in the tibial intra-bone graft ($$ {\varDelta T}_{2s}^{\ast } $$ ΔT 2 s : 0.19 ± 0.18 ms, P < 0.05; Δfbw: 4% ± 4%, P < 0.05). Lower $$ {T}_{2s}^{\ast } $$ T 2 s (− 0.09 ± 0.11 ms, P < 0.05) was observed at 3-months when comparing the intra-bone graft to the graft/bone interface in the femoral tunnel. The same comparisons at the 6-months also yielded relatively lower $$ {T}_{2s}^{\ast } $$ T 2 s (− 0.09 ± 0.12 ms, P < 0.05). Conclusion The proposed abbreviated 3D UTE MRI paradigm is capable of assessing the ACL graft remodeling process in a clinically translatable acquisition time. Longitudinal changes in $$ {T}_{2s}^{\ast } $$ T 2 s and fbw of the ACL graft were observed.

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,Rheumatology

Cited by 12 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3