Weightbearing after combined medial and lateral plate fixation of AO/OTA 41-C2 bicondylar tibial plateau fractures: a biomechanical study

Author:

Thamyongkit Sorawut,Abbasi Pooyan,Parks Brent G.,Shafiq Babar,Hasenboehler Erik A.

Abstract

Abstract Background Combined medial and lateral plate fixation is recommended for complex tibial plateau fractures with medial fragments or no cortical bone contact. Although such fixation is adequate to resist forces during range of motion, it may be insufficient to support immediate postoperative weightbearing. Here, we analyzed displacement, stiffness, and fixation failure during simulated full weightbearing of bicondylar tibial plateau fractures treated with combined medial and lateral locking plate fixation. Methods We used 10 fresh-frozen adult human cadaveric tibias and mated femurs. Osteotomies were performed with an oscillating saw and cutting template to simulate an AO Foundation and Orthopaedic Trauma Association (AO/OTA) 41-C2 fracture (simple articular, multifragmentary metaphyseal fracture). Specimens were anatomically reduced and stabilized with combined medial and lateral locking plates (AxSOS, Stryker, Mahwah, NJ). Specimens were loaded axially to simulate 4 weeks of walking in a person weighing 70 kg. The specimens were cyclically loaded from 200 N to a maximum of 2800 N. Then, if no failure, loading continued for 200,000 cycles. We measured displacement of each bone fragment and defined fixation failure as ≥5 mm of displacement. Construct stiffness and load at failure were calculated. Categorical and continuous data were analyzed using Chi-squared and unpaired t-tests, respectively. Results Mean total displacement values after 10,000 loading cycles were as follows: lateral, 0.4 ± 0.8 mm; proximal medial, 0.3 ± 0.7 mm; distal medial, 0.3 ± 0.6 mm; and central 0.4 ± 0.5 mm. Mean stiffness of the construct was 562 ± 164 N/mm. Fixation failure occurred in 6 of 10 specimens that reached 5 mm of plastic deformation before test completion. In the failure group, the mean load at failure was 2467 ± 532 N, and the mean number of cycles before failure was 53,155. After test completion, the greatest displacement was found at the distal medial fracture site (2.3 ± 1.4 mm) and lateral fracture site (2.2 ± 1.7 mm). Conclusions Although combined medial and lateral plate fixation of complex tibial plateau fractures provides adequate stability to allow early range of motion, immediate full weightbearing is not recommended.

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,Rheumatology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3