Hybrid versus total sublaminar wires in patients with spinal muscular atrophy undergoing scoliosis surgery

Author:

Chou Shih-Hsiang,Li Wen-Wei,Lu Cheng-Chang,Lin Kun-Ling,Lin Sung-Yen,Shen Po-Chih,Tien Yin-Chun,Huang Hsuan-Ti

Abstract

Abstract Background Early versions of spinal muscular atrophy (SMA) scoliosis correction surgery often involved sublaminar devices. Recently, the utilization of pedicle screws has gained much popularity. Pedicle screws are generally believed to provide additional deformity correction, but pedicle size and rotational deformity limit their application in the thoracic spine, resulting in a hybrid construct involving pedicle screws and sublaminar wire. Studies of the efficacy of hybrid instrumentation in SMA scoliosis are often limited by the scarcity of the disease itself. In this study, we aimed to compare the surgical outcomes between hybrid constructs involving pedicle screws and sublaminar wire and sublaminar wire alone in patients with SMA scoliosis. Methods We retrospectively reviewed the clinical records and radiographic assessments of patients with SMA scoliosis who underwent corrective surgery between 1993 and 2017. The radiographic assessments included deformity correction and progressive changes in the major curve angle, pelvic tilt (PT) and coronal balance (CB). The correction of deformities was observed postoperatively and at the patient’s 2-year follow-up to test the efficacy of each type of construct. Results Thirty-three patients were included in this study. There were 14 and 19 patients in the wiring and hybrid construct groups, respectively. The hybrid construct group demonstrated a higher major curve angle correction (50.5° ± 11.2° vs. 36.4° ± 8.4°, p < 0.001), a higher apical vertebral rotation correction (10.6° ± 3.9° vs. 4.8° ± 2.6°, p < 0.001), and a reduced progression of the major curve angle at the 2-year follow-up (5.1° ± 2.9° vs. 8.7° ± 4.8°, p < 0.001). A moderate correlation was observed between the magnitude of correction of the apical vertebral rotation angle and the major curve (r = 0.528, p = 0.002). Conclusion This study demonstrated that hybrid instrumentation can provide a greater magnitude of correction in major curve and apical rotation as well as less major curve progression than sublaminar wire instrumentation alone in patients with SMA scoliosis. Level of evidence III

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,Rheumatology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3