Evaluation of the coracoid bone tunnel placement on Dog Bone™ button fixation for acromioclavicular joint dislocation: a cadaver study combined with finite element analysis

Author:

Gao Rangshan,Zhang Wendong,Yang Yuxia,Zhang Yucheng,Hu Yangyang,Wu Honghai,Liu Mingsheng,Fei Wenyong,Wang Jingcheng

Abstract

Abstract Background Dog Bone™ button fixation is frequently used to treat acromioclavicular joint (ACJ) dislocation. However, various studies have reported complications after fixation. Objective To investigate the effect of the coracoid bone tunnel location on the treatment of ACJ dislocation through single-tunnel coracoclavicular (CC) ligament fixation with the Dog Bone™ button. Methods Six cadaveric shoulders were used. Each specimen was subjected to five testing conditions in the following order: (1) normal ACJ (Gn); (2) acromioclavicular and CC ligaments were removed (G0); (3) CC ligament reconstruction was performed using the Dog Bone™ technique, and the coracoid bone tunnel was at the center of the coracoid base (G1); (4) reconstruction was performed at 5 mm distal from the G1 site, along the axis of the coracoid (G2); (5) reconstruction was performed at 10 mm distal from the G1 site, along the axis of the coracoid (G3). The angles of pronation and supination of the clavicle under the same load (30 N) were measured. Next, a finite element (FE) model was created using computed tomography (CT) images of the normal shoulder. Model 1 (M1), model 2 (M2), and model 3 (M3) correspond to G1, G2, and G3, respectively. A force of 70 N was applied as a vertical upward load to the distal clavicle. Subsequently, the von Mises stress, the strain LE along the FiberWire, and the displacement nephogram of the three models were obtained. Results After single-tunnel CC ligament fixation using the Dog Bone™ technique, the clavicle in the G2 group (20.50 (19.50, 21.25) °, 20.00 (18.75, 21.25) °) had the best rotational stability. The peak von Mises stress, the strain LE along the FiberWire, and the maximum displacement were smaller in M2 than in M1 and M3. Conclusions When the coracoid bone tunnel was located 5 mm anterior to the center of the coracoid base (along the axis of the coracoid), the clavicle showed greater rotational stability.

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,Rheumatology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3