The C2 isthmus screw provided sufficient biomechanical stability in the setting of atlantoaxial dislocation-a finite element study

Author:

Lu Minming,Wang Zhenqiang,Yuan Bo,Tang Yifan,Gu Changjiang,Zhou Shengyuan,Chen Xiongsheng

Abstract

Abstract Background The emerging of the C2 isthmus screw fixation technique is gaining popularity in the setting of atlantoaxial dislocation or other conditions requiring fixation of C2. However, the biomechanical stability of this fixation is poorly understood. Purpose To compare and elucidate the biomechanical stability of C2 pedicle screw (C2PS), C2 isthmus screw (C2IS) and C2 short isthmus screw (C2SIS) fixation techniques in atlantoaxial dislocation (AAD). Method A three-dimensional finite element model (FEM) from occiput to C3 was established and validated from a healthy male volunteer. Three FEMs, C1 pedicle screw (PS)-C2PS, C1PS-C2IS, C1PS-C2SIS were also constructed. The range of motion (ROM) and the maximum von Mises stress under flexion, extension, lateral bending and axial rotation loading were analyzed and compared. The pullout strength of the three fixations for C2 was also evaluated. Result C1PS-C2IS model showed the greatest decrease in ROM with flexion, extension, lateral bending and axial rotation. C1PS-C2PS model showed the least ROM reduction under all loading conditions than both C2IS and C2SIS. The C1PS-C2PS model had the largest von Mises stress on the screw under all directions followed by C1PS-C2SIS, and lastly the C1PS-C2IS. Under axial rotation and lateral bending loading, the three models showed the maximum and minimum von Mises stress on the screw respectively. The stress of the three models was mainly located in the connection of the screw and rod. Overall, the maximum screw pullout strength for C2PS, C2IS and C2SIS were 729.41N, 816.62N, 640.54N respectively. Conclusion In patients with atlantoaxial dislocations, the C2IS fixation provided comparable stability, with no significant stress concentration. Furthermore, the C2IS had sufficient pullout strength when compared with C2PS and C2SIS. C2 isthmus screw fixation may be a biomechanically favourable option in cases with AAD. However, future clinical trials are necessary for the evaluation of the clinical outcomes of this technique.

Publisher

Springer Science and Business Media LLC

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3