Author:
Tang Benqiang,Xu Songjie,Chen Xueming,Cui Libin,Wang Yanhui,Yan Xin,Liu Yadong
Abstract
Abstract
Background
The impact of intravertebral cleft (IVC) on cement leakage in percutaneous vertebroplasty (PVP) for osteoporotic vertebral compression fractures (OVCFs) has been discussed. However, the results were conflicting, as the study population and cement leakage classification were heterogeneous. The aim of the study was to evaluate the impact of IVC on the incidence of leakage through vein, leakage through cortex as well as general leakage in PVP for OVCFs.
Methods
All patients with OVCFs who underwent PVP between January 2016 and June 2019 at our institution were retrospectively reviewed. Patients were eligible for this case-control study if they were diagnosed as single level fracture in spine. After inclusive and exclusive criteria were met, a total of 139 patients with IVC were enrolled as the study group. Non-IVC controls were matched in a 1:1 ratio in age (within 3 years), sex and fracture severity with patients in study group. Cement leakage were classified into four types [type B (through basivertebral vein), type S (through segmental vein), type-C (through a cortical defect), and type D (intradiscal leakage)], furtherly into two types [venous type (type-B or/and type S) and cortical type (type-C or/and type-D)]. A general leakage rate and a specific leakage rate per each type were compared between both groups.
Results
Each group included 139 patients. Groups were homogenous for age, sex, fracture severity, fracture location, fracture type, cement volume, puncture approach and property of cement. Compared with control group, IVC group had a significantly lower rate of type-B (20.9% vs. 31.7%, P = 0.041), type-S (24.5% vs. 52.5%, P = 0.000), and venous type leakage (37.4% vs. 67.6%, P = 0.000), a significantly higher rate of type-C (25.9% vs. 12.2%, P = 0.004), type-D (16.5% vs. 6.5%, P = 0.009), and cortical type leakage (40.3% vs. 16.5%, P = 0.000), no significant difference on the rate of general leakage (67.6% vs. 76.3%, P = 0.109).
Conclusion
IVC decreased the risk of cement leakage through vein and increased the risk of cement leakage through cortex. However, it had no significant effect on the occurrence of general leakage.
Publisher
Springer Science and Business Media LLC
Subject
Orthopedics and Sports Medicine,Rheumatology
Reference35 articles.
1. Chang JZ, Bei MJ, Shu DP, et al. Comparison of the clinical outcomes of percutaneous vertebroplasty vs. kyphoplasty for the treatment of osteoporotic Kümmell’s disease: a prospective cohort study. BMC Musculoskelet Disord. 2020;21(1):238.
2. Kim YC, Kim YH, Ha KY. Pathomechnism of intravertebal clefts in osteoporotic compression fractures of the spine. Spine J. 2014;14(4):659–66. https://doi.org/10.1016/j.spinee.2013.06.106.
3. Mirovsky Y, Anekstein Y, Shalmon E, Peer A. Vacuum clefts of the vertebral bodies. AJNR Am J Neuroradiol. 2005;26(7):1634–40.
4. Kim DY, Lee SH, Jang JS, et al. Intravertebral vacuum phenomenon in osteoporotic compression fracture: report of 67 cases with quantitative evaluation of intravertebral instability. J Neurosurg. 2004;100(1 Suppl Spine):24–31.
5. Yu W, Jiang X, Liang D, et al. Intravertebral vacuum cleft and its varied locations within osteoporotic vertebral compression fractures: effect on therapeutic efficacy. Pain Physician. 2017;20(6):E979–86. https://doi.org/10.36076/ppj.20.5.E979.