A novel biplanar positioning technique to guide iliosacral screw insertion: a retrospective study

Author:

Zhao Yangyang,Cui Pengju,Xiong Zhenggang,Zheng Jiachun,Xing Deguo

Abstract

Abstract Purpose To evaluate the safety and benefits of the biplanar position technique on operative time, radiation exposure, and screw placement accuracy. Methods In this study, we retrospectively evaluated the records of 64 patients with pelvic fractures (Tile B and C) between October 2020 and September 2021. According to the surgical methods selected by the patients, the patients were divided into a biplanar positioning technique group (biplanar group), a Ti-robot navigation group (Ti-robot group), and a traditional fluoroscopy-guided technique group (traditional group). Length of operation, blood loss, intra-operative radiation exposure fracture reduction, and the quality of screw positioning were compared among the three groups. Results One hundred three screws were implanted in 64 patients (biplanar group 22, Ti-robot group 21, traditional group 21). The average operation time was significantly less in the biplanar group (26.32 ± 6.32 min) than in the traditional group (79.24 ± 11.31 min), but significantly more than in the Ti-robot group (15.81 ± 3.9 min). The radiation exposure was similar in the biplanar group (740.53 ± 185.91 cGy/cm2) and Ti-robot group (678.44 ± 127.16 cGy/cm2), both of which were significantly more than in the traditional group (2034.58 ± 494.54 cGy/cm2). The intra-operative blooding loss was similar in the biplanar group (12.76 ± 3.77 mL) and the Ti-robot group (11.92 ± 4.67 mL), both of which were significantly less than in the traditional group (29.7 ± 8.01 mL). The Screw perforation was slightly lower in the biplanar group (94.1%) than in the Ti-robot group (97.2%) but was significantly higher than in the traditional group (75.7%). Conclusions The biplanar positioning technique is as accurate and safe as computer-navigated systems for percutaneous iliosacral screw insertion, associated with shorter surgical time, lower intra-operative radiation exposure, and more accuracy compared to traditional fluoroscopy.

Funder

Deguo Xing

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,Rheumatology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3