Cup orientation following posterior approach THA – the effect of different visual aids and pelvic supports

Author:

Innmann Moritz M.,Verhaegen Jeroen,Merle Christian,Beaulé Paul E.,Meermans Geert,Grammatopoulos George

Abstract

Abstract Introduction This study aims to compare cup inclination achieved (1) Using two orientation guides, whilst using the same 3-point pelvic positioner and (2) Using two types of pelvic positioners, whilst measuring intra-operative cup inclination with an inclinometer. Materials and methods This is a prospective, diagnostic cohort study of a consecutive series of 150 THAs performed through a posterior approach. Two types of 3-point pelvic positioners were used (Stulberg and modified Capello Hip Positioners) and the cup was positioned freehand using one of two orientation guides (mechanical guide or digital inclinometer). Intra-operative inclination was recorded, radiographic cup inclination and anteversion were measured from radiographs. The differences in inclination due to pelvic position (ΔPelvicPosition) and orientation definitions (ΔDefinition) were calculated. Target radiographic inclination and anteversion was 40/20° ± 10°. Results There was no difference in radiographic cup inclination/ (p = 0.63) using a mechanical guide or digital inclinometer. However, differences were seen in ΔPelvicPosition between the positioners ((Stulberg: 0° ± 5 vs. Capello: 3° ± 6); p = 0.011). Intra-operative inclination at implantation was different between positioners and this led to equivalent cases within inclination/anteversion targets (Stulberg:84%, Capello:80%; p = 0.48). Conclusions With the pelvis securely positioned with 3-point supports, optimum cup orientation can be achieved with both alignment guides and inclinometer. Non-optimal cup inclinations were seen when intra-operative inclinations were above 40° and below 32°, or the ΔPelvicPosition was excessive (> 15°; n = 2). We would thus recommend that the intra-operative cup inclination should be centered strictly between 30° and 35° relative to the floor. Small differences exist between different type of pelvic positioners that surgeons need to be aware off and account for.

Funder

Universitätsklinikum Heidelberg

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,Rheumatology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3