Evaluation of the clinical efficacy of using an inverted triangular cannulated compression screw in combination with positive or negative buttress reduction for the healing of femoral neck fractures

Author:

Wang Gang,Tang Cui,Tang Yong,Wang Rui,Shen Tugang,Xu Chundao,Yu Jian,Li Gaokai

Abstract

Abstract Objective We aimed to compare the clinical efficacy of inverted triangular cannulated compression screws combined with Gotfried positive or negative buttress reduction in the healing of femoral neck fractures. Methods Between October 2017 and March 2021, 55 patients with femoral neck fractures underwent treatment using inverted triangular cannulated compression screws combined with Gotfried positive or negative buttress reduction. Among these patients, 29 received inverted triangular cannulated compression screws combined with Gotfried positive buttress reduction treatment. This group consisted of 16 males and 13 females, with an average age of 43.45 ± 8.23 years. Additionally, 26 patients received inverted triangular cannulated compression nails combined with Gotfried negative buttress reduction treatment. This group included 14 males and 12 females, with an average age of 41.96 ± 8.69 years. Postsurgery, various measurements were taken, including the degree of shortening of the femoral neck, degree of bone nonunion, degree of fixation failure, degree of ischemic necrosis of the femoral head, and Harris score of the hip joint. Results All patients were followed up for a minimum of 18 months. The group that underwent treatment with an inverted triangular cannulated compression screw combined with Gotfried positive buttress reduction did not experience any cases of bone nonunion, fixation failure, or ischemic necrosis of the femoral head. In the group that received treatment with inverted triangle cannulated compression screws combined with Gotfried negative buttress reduction, there was one case of bone nonunion, three cases of early fixation failure, and one case of ischemic necrosis. Ultimately, five patients (19.23% of the total) underwent joint replacement surgery. The average shortening lengths in the vertical plane were 4.07 ± 1.98 mm and 8.08 ± 3.54 mm, respectively. In the horizontal plane, the average shortening lengths were 3.90 ± 1.57 mm and 7.77 ± 3.31 mm, respectively. At the last follow-up, the group that received Gotfried positive buttress reduction had a greater Harris hip joint score. Conclusion The success rate of combining inverted triangular cannulated compression screws with Gotfried positive buttress reduction surgery is relatively high. This surgical approach effectively prevents femoral neck shortening and improves hip joint function. Moreover, it is crucial to avoid negative buttress reduction when managing femoral neck fractures.

Funder

Huzhou City science and technology plan project

Medical Science and Technology Project of Zhejiang Province

Publisher

Springer Science and Business Media LLC

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3