Author:
Wang Yitian,Min Li,Lu Minxun,Zhou Yong,Wang Jie,Zhang Yuqi,Yu Xinzhu,Tang Fan,Luo Yi,Duan Hong,Tu Chongqi
Abstract
Abstract
Background
En bloc excision has been increasingly used for the management of giant cell tumors (GCTs) in the distal radius. An osteoarticular allograft has been used extensively for decades, and custom-made prosthesis reconstruction has been more recently applied. We aimed to compare the clinical outcomes of the two procedures.
Methods
We retrospectively analyzed 30 patients with Campanacci III or recurrent GCTs of the distal radius for follow-up at a mean of 33.2 months. In total, 15 underwent osteoarticular allograft reconstruction (allograft group) and 15 received cementless three-dimensional (3D)-printed prosthesis reconstruction (prosthesis group) between March 18, 2013, and May 20, 2018. All patients underwent by clinical and radiological examinations, including pre- and postoperative active range of motion (ROM) of the wrist, VAS score, grip strength, degenerative change of wrist, Mayo wrist score and Musculoskeletal Tumor Society (MSTS) score. Complications were evaluated using the Henderson classification.
Results
Both groups showed significantly increased ROM, grip strength, Mayo score and MSTS score postoperatively. Furthermore, the extension, flexion, MSTS, and Mayo score were significantly higher in the prosthesis group. There was no significant difference in grip strength and VAS between the groups. In allograft group, one patient had a late infection one had resorption of allograft without allograft bone fracture. and four had wrist subluxation. All patients had degenerative changes (mean 9 months). In the prosthesis group, three patients developed wrist subluxation, three had separation of the distal radioulnar joint, and none of the patients developed wrist degeneration.
Conclusions
Our study compared the objective functional outcomes and complications of two reconstructive methods for Campanacci III or recurrent GCT in the distal radius. 3D-printed prosthesis replacement can partially preserve wrist function better than allograft reconstruction in the short-term. During the design of 3D-printed prosthesis, preoperative morphological assessment of the affected proximal row carpal is helpful to control postoperative dislocation. After allograft reconstruction, wrist degeneration, which has been demonstrated in all patients, severely influence their wrist function. Therefore, compared to allograft reconstruction, 3D-printed prosthesis reconstruction has irreplaceable advantages at early-stage application, especially in wrist function, however, further studied with a larger number of cases and longer follow-up.
Publisher
Springer Science and Business Media LLC
Subject
Orthopedics and Sports Medicine,Rheumatology
Cited by
24 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献