Standard radiographic values for the acetabulum in Japanese adolescents: a cross-sectional study

Author:

Nishimura Takahiro,Watanabe Hideaki,Taki Naoya,Kikkawa Ichiro,Takeshita Katsushi

Abstract

Abstract Background Most previous reports of normal acetabular radiographic values focused on adults or elderly people. Recent reports have described premature hip osteoarthritis in adolescents not caused by acetabular dysplasia. In addition, there is a certain failure rate of surgical treatment for young patients with borderline acetabular dysplasia. Accurate indices for treatment of adolescent hips are unclear because standard measurement values of the adolescent acetabulum have not been reported. Methods This cross-sectional study involved 552 Japanese adolescents aged 12–18 years who had scoliosis or suspected scoliosis and asymptomatic hips. All persons underwent plain standing anteroposterior whole-spine radiography, and measurements were obtained using the pelvic part of the radiograph. We excluded persons who were unable to correctly perform measurements because of conditions such as pelvic rotation or lateral inclination and persons in whom closure of the triradiate cartilage or closure of the secondary ossification centers of the acetabulum had not yet occurred. In 1101 hips, we measured the lateral center–edge angle (LCEA), Tönnis angle, Sharp angle, acetabular head index (AHI), lateral subluxation (LS), vertical subluxation (VS), and peak-to-edge distance (PED). We evaluated the correlation coefficient and coefficient of determination between each parameter and age, height, body weight, and body mass index (BMI) and assessed the intra- and inter-rater reliability of each radiographic parameter. Results Among all hips, the mean of each parameter was as follows: LCEA, 27.9° ± 4.8°; Tönnis angle, 5.0° ± 3.7°; Sharp angle, 44.1° ± 3.1°; AHI, 82.1% ± 5.5%; LS, 5.4 ± 1.4 mm; VS, 0.3 ± 1.2 mm; and PED, 14.0 ± 2.3 mm. The correlation between each parameter and age, height, body weight, and BMI was considerably low. Intra- and inter-rater reliability was moderate or good for almost all parameters. Conclusions The values for each radiographic parameter of the acetabulum in this study are considered standard for the adolescent acetabulum without age-related changes. Some parameters differ slightly from the normal values for adults or elderly people in previous reports; thus, we suggest careful evaluation of these parameters for adolescents.

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,Rheumatology

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3