Author:
Lee Han Jin,Kim Hong Seok,Yoo Jeong Joon
Abstract
Abstract
Background
In metaphyseo-diaphyseal (M-D) mismatched Dorr A femurs, it is difficult to achieve proper fixation with a type 1 stem. Proper interpretation of the geometry of the femur is integral at the preoperative stage in an M-D mismatched femur, but there has been a scarcity of studies on the radiologic indices. Therefore, we analyze the previous radiologic indices and suggest the novel ones for M-D mismatched femurs.
Methods
Our study was a retrospective review of preoperative radiographs of patients who underwent total hip arthroplasty with the smallest type 1 stem or with type 3 C stem at a single institution from July 2014 to March 2022. A Type 3 C stem was used when the smallest type 1 stem failed to achieve metaphyseal fixation. One hundred twenty-six patients were categorized into two main groups. Canal-flare index, canal-calcar ratio, modified morphological cortical index, and two novel indices (lesser trochanter-to-distal ratio-α and -β [LDR-α and -β]) were assessed on preoperative pelvic radiographs.
Results
Multivariate and ROC analysis demonstrated that high LDR-β (Exp[B]: 485.51, CI: 36.67-6427.97, p < 0.001) was associated with a more mismatched tendency group and had clinically acceptable discriminatory power (AUC: 0.765, CI: 0.675–0.855, p < 0.001) between the two cohorts.
Conclusion
Correct assessment of preoperative femoral morphology would be fundamental in the selection of a suitable stem. The ratio based on 3 cm below the lesser trochanter of the femur seemed crucial. We recommend evaluating the newly described radiological index preoperatively in M-D mismatched Dorr A femur for planning precisely and selecting a proper stem.
Publisher
Springer Science and Business Media LLC