Author:
Lim Jun-Hyuk,Hwang Jaeyeon,Kim Sungmin,Kim Myung-Sun
Abstract
Abstract
Background
The calcar of the proximal humerus is a fundamental structure for medial humeral column support. This study aimed to assess the outcome of osteosynthesis across cases of unstable proximal humerus fractures (PHFs) with medial calcar comminution, following treatment with a PHILOS locking plate and medial support screw (MSS).
Methods
Between January 2010 and December 2018, we retrospectively analyzed the outcomes of 121 cases of osteosynthesis for PHFs with medial column disruption. For the medial support, at least one oblique screw was inserted within 5 mm of the subchondral bone in the inferomedial quadrant of the humeral head. All patients were categorized into two groups: 26 patients in the single MSS group, and 95 in the multiple MSS group. Follow-up after at least an year involved clinical and radiographic outcome evaluations, and correspondingly measuring the Constant-Murley score, University of California, Los Angeles (UCLA) shoulder scale, pain visual analogue scale (VAS), major complications, neck-shaft angle (NSA), humeral head height (HHH), and the eventual time to bone union. Risk factors for the major complications were assessed by multivariate logistic regression analyses.
Results
The cohort’s mean age was 64.4 ± 15.4 years, and the mean follow-up duration was 19.5 ± 7.6 months. At the final follow-up, between the single MSS and multiple MSS groups, no significant differences in the Constant-Murley score (p = 0.367), UCLA score (p = 0.558), VAS (p = 0.571), time to bone union (p = 0.621), NSA loss (p = 0.424), and HHH loss (p = 0.364) were observed. The incidence of complications (p = 0.446) based on the number of MSS were not significantly different. The initial insufficient reduction after surgery (of NSA < 125°) was found to be a significant risk factor for post-surgical complications.
Conclusions
To treat unstable PHFs, the use of at least one MSS along with a locking plate system is sufficient to achieve satisfactory outcomes. Successful operative treatment using a locking plate for PHF treatment is inherent in anatomical fracture reduction, coupled with medial column support.
Publisher
Springer Science and Business Media LLC
Reference38 articles.
1. Patel AH, Wilder JH, Ofa SA, Lee OC, Savoie MJ III, et al. Trending a decade of proximal humerus fracture management in older adults. JSES Int. 2022;6:137–43.
2. Karl JW, Olson PR, Rosenwasser MP. The epidemiology of upper extremity fractures in the United States, 2009. J Orthop Trauma. 2015;29:e242–44.
3. Zhang Z, Li Y, Zhao Y, Lu Y, Zhu Y, Jiang C. What are the long-term outcomes of locking plates for nonosteoporotic three-part and four-part proximal humeral fractures with a minimum 10-year follow-up period? Clin Orthop Relat Res. 2024;482:831–40.
4. Jhamnani R, Dhanda MS, Surana A. Study of functional outcome and postoperative complications among proximal Humerus fracture patients treated with proximal Humerus Internal Locking System (PHILOS) plating. Cureus. 2023;15:e42411.
5. Lee CH, Kim SY. Effectiveness of locking compression plate for proximal humeral fracture in elderly patients without structural bone grafting: age group of 65–79 compared to 80 and above. Eur J Orthop Surg Traumatol. 2023;33:3461–7.