Clinical and radiological outcome after anterior cruciate ligament reconstruction using the T-lock Osteotrans resorbable tendon anchor: early experience and midterm follow-up

Author:

Bangert Y.,Jaber A.,Wünnemann F.,Berrsche G.,Streich N.,Rehnitz C.,Ott H.,Barié A.

Abstract

Abstract Purpose Reconstruction of the Anterior cruciate ligament (ACL) using tendon grafting is an established method for restoring knee function and stability. Multiple methods are established for graft fixation. Several involve anchoring the autograft distant to the joint with hardware that remains implanted. This study reports the first early to midterm results in patients who received ACL reconstruction (ACLR) using the T-Lock Osteotrans femoral near joint fixation method with a tibial fixation using the BioactIF Osteotrans interference screw. Methods This consecutive prospective series included 20 Patients (14 Male, 6 Female) with a primary ACL rupture. All patients were treated with an ACLR using a semitendinosus autograft fixated with the T-Lock Osteotrans and were followed-up postoperatively. The following parameters were assessed: Side-to-side difference of the posterior-anterior translation measured using the KT-1000 arthrometer, Tegner activity score, Lysholm score, IKDC subjective knee evaluation form. Magnetic resonance imaging (MRI) was done to assess tunnel enlargement and integrity of the anchoring device. Results The average follow-up duration was 2 years (range 1–4.2 years). One patient was lost to follow-up. Two Patients suffered a traumatic ACL re-rupture 2 years postoperatively and received a 2-stage revision ACLR. Difference in the posterior-anterior translation was 1.8 mm (range 0–5). The median Tegner score was 6 (range 4–10) and 9 patients (45%) returned to their preinjury level of activity. The mean IKDC subjective knee evaluation form scored 91 points (range 77–100). The mean Lysholm score was 86 points (74–96). All mentioned scores were significantly better compared to preoperative values. No relevant tunnel enlargement was seen on MRI. The anchoring device was evaluated to be intact in all patients. Conclusion ACLR with the aforementioned procedure leads to good clinical and radiological outcome.

Funder

Richard Wolf

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,Rheumatology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3