A modified anatomical posterior cruciate ligament reconstruction technique using the posterior septum and posterior capsule as landmarks to position the low tibial tunnel

Author:

Niu Yingzhen,Chen Zhen,Jin Lingpeng,Zheng Yi,Zhang Zhuangdai,Wang Fei,Zhang Zhenfeng,Ma Jun,Men Xiaoqian,Dong Jiangtao

Abstract

Abstract Background Lowering the exit position of the tibial tunnel can improve the clinical efficacy of posterior cruciate ligament (PCL) reconstruction, however, there is no unified positioning standard. This study aimed to use novel soft tissue landmarks to create a low tunnel. Methods A total of 14 human cadaveric knees and 12 patients with PCL injury were included in this study. Firstly, we observed the anatomical position between the PCL, posterior septum, and other tissue, and evaluated the relationship between the center of the low tibial tunnel (SP tunnel) and posterior septum and distal reflection of posterior capsule, and using computed tomography (CT) to evaluate distance between the center of the SP tunnel with bony landmarks. Then, evaluated the blood vessels content in the posterior septum with HE staining. Finally, observed the posterior septum and distal reflection of the posterior capsule under arthroscopy to explore the clinical feasibility of creating a low tibial tunnel, and assessed the risk of surgery by using ultrasound to detect the distance between the popliteal artery and the posterior edge of tibial plateau bone cortex. Results In all 14 cadaveric specimens, the PCL tibial insertions were located completely within the posterior medial compartment of the knee. The distance between the center of the SP tunnel and the the articular surface of tibial plateau was 9.4 ± 0.4 mm. All SP tunnels retained an intact posterior wall, which was 1.6 ± 0.3 mm from the distal reflection of the posterior capsule. The distances between the center of the SP tunnel and the the articular surface of tibial plateau, the champagne glass drop-off were 9.2 ± 0.4 mm (ICC: 0.932, 95%CI 0.806–0.978) and 1.5 ± 0.2 mm (ICC:0.925, 95%CI 0.788–0.975) in CT image. Compared with the posterior capsule, the posterior septum contained more vascular structures. Last, all 12 patients successfully established low tibial tunnels under arthroscopy, and the distance between the posterior edge of tibial plateau bone cortex and the popliteal artery was 7.8 ± 0.3, 9.4 ± 0.4 and 7.4 ± 0.3 mm at 30°, 60° and 90° flexion angels after filling with water and supporting with shaver in posterior-medial compartment of knee joint. Conclusions A modified low tibial tunnel could be established in the PCL anatomical footprint by using the posterior septum and posterior capsule as landmarks.

Funder

“14th Five-Year” clinical medicine Innovation Research Team Support program of Hebei Medical University

Science and Technology Department of Hebei Province assisted Xinjiang science and technology plan project

National Natural Science Foundation of China

Publisher

Springer Science and Business Media LLC

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3