Evaluation of Judet view radiographs accuracy in classification of acetabular fractures compared with three-dimensional computerized tomographic scan: a retrospective study

Author:

Tazeabadi Sepideh Abdi,Noroozi Shima Ghafourian,Salehzadeh Meysam,Bahardoust Mansour,Farahini Hossein,Hajializade Mikaiel,Yeganeh Ali

Abstract

Abstract Background In the current diagnostic procedure, generally, both plain radiographs and 3D-CT scans are used for the diagnosis of acetabular fractures. There is no consensus regarding the value of a three-dimensional computerized tomographic (3D-CT) scan alone in the classification of acetabular fractures. In this study, we compared the accuracy of 3D-CT scan and plain radiography through the evaluation of their agreement with the intraoperative surgeon’s classification. Method In a retrospective study, patients who were referred to our center with an acetabular fracture and underwent surgical treatment were included. The classification of acetabular fractures was performed once using Judet view plain radiographs and once using a 3D-CT scan by the corresponding one Experienced musculoskeletal radiologist one independent trauma fellowship-trained orthopaedic who routinely treat acetabular fractures and based on Letournel and Judet classification (17 and 23 years of experience respectively). Cohen’s kappa value was used for the assessment agreement between the two imaging modalities, as well as between the imaging modalities and intraoperative classification. Results Medical files of 152 patients with acetabular fracture were retrospectively reviewed. A kappa value of 0.236 was obtained as the agreement level between radiographs and intraoperative findings (p < 0.001). A kappa value of 0.943 was obtained as the agreement level between 3D-CT and intraoperative classification (p < 0.001). An agreement level of 0.264 was found between the Judet radiographs and 3D-CT scans (p < 0.001). Conclusions 3D-CT scans are reliable enough in the classification of acetabular fractures, and plain radiographs could be omitted to avoid radiation exposure as well as to reduce the cost for patients who sustain acetabular fractures.

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,Rheumatology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3